Kool Seal may be the best roof coating because it clings to your roof in all temperatures. It provides good protection against moisture, so it is suitable for humid areas.This product forms a thick barrier for the roof, which can reflect 90% of the sun’s rays. Whether in the hottest summer or in the coldest winter, this product maintains durable and protective. Spray Coating Services
Spray painting poses health hazards that affect the respiratory, nervous, and circulatory systems. Similarly, using solvents to clean one's hands of paint marks and residue may cause skin irritation or even more serious issues since many are carcinogenic or neurotoxic. There are risks involved in working with substances such as paint and thinner, which contain compounds that are potentially harmful to health, or even fatal.[9] Insulation Spray Coating
Water beading is impressive using CMX. Wife's car sat out all day in rain in a outdoor parking lot, she drove home and car looked almost dry! Car looks like I just washed it. Shaking CMX before application and during application, still getting small white beads. I think it's residue after spraying off and wiping off immediately. I think CMX evaporates on towel and is creating small beads that fall onto car, like compound or polish that leaves dust residual, but these are tiny white bead particles...That's the only pain I see to using this product.
Tools: Ames® premium elastomeric roof coatings can be applied with a paint brush, a push broom, a paint roller or a commercial/industrial airless sprayer. In addition, you may need Ames® Peel & Stick™ Seam Tape, a pair of scissors and utility knife. For larger commercial jobs, we recommend a commercial/industrial airless sprayer. Call 888-345-0809 with questions or click here for sprayer specifications.
Thermal spraying can provide thick coatings (approx. thickness range is 20 microns to several mm, depending on the process and feedstock), over a large area at high deposition rate as compared to other coating processes such as electroplating, physical and chemical vapor deposition. Coating materials available for thermal spraying include metals, alloys, ceramics, plastics and composites. They are fed in powder or wire form, heated to a molten or semimolten state and accelerated towards substrates in the form of micrometer-size particles. Combustion or electrical arc discharge is usually used as the source of energy for thermal spraying. Resulting coatings are made by the accumulation of numerous sprayed particles. The surface may not heat up significantly, allowing the coating of flammable substances. Spray Coating Services
Ever wonder why it's so hot and wet inside a metal building that has spray foam insulation, in the summer and so cold and wet in winter? The metal skin magnifies the heat of the summer and frigid temperatures of the winter. Metal is a very good conductor of heat and cold. In hot weather, metal framing and sheeting rapidly radiate the sun's heat into a building. In cold weather it rapidly releases the heat out of your building. When warm air comes in contact with the cool metal sheet, condensation occurs. 
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Coating Services
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Coating Services
Weather & Drying Guidelines: Ames® Super Primer™, Maximum-Stretch® and Iron Coat® is best applied between 50° to 90° F (10° to 32° C) on warm dry surfaces. Apply when the streets are dry, the sun is in the sky and no inclement weather is forecast. Starts to dry in about 2-8 hours, depending on thickness of application and weather. It is recommended to allow a minimum of 24 hours between coats with no rain in the forecast and no freezing temperatures. Low temperatures, high humidity and evening and morning dew will require increased drying/curing time. Do not apply after 2pm for best drying. The earlier you can put it on, the better. Make sure any morning dew is completely dried off before proceeding.

The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments. Insulation Spray Coating
Most electric powered airless pumps have an electric motor connected through a gear train to the paint piston pump. Pressure is achieved by stopping and starting the motor via a pressure sensor (also called a transducer); in more advanced units, this is done by digital control in which the speed of the motor varies with the demand and the difference from the pressure set-point, resulting in a very good pressure control. Some direct drive piston pumps are driven by a gasoline engine with pressure control via an electric clutch. In electric diaphragm pumps, the motor drives a hydraulic piston pump that transmits the oil displaced by the piston, to move the diaphragm. Insulation Spray Coating
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend? Insulation Spray Coating
Polyurethane Spray Foam Insulation is used in industries ranging from mining to movies, from cold storage to marine flotation. Spray Foam Insulation’s ability to seal out air and insulate quickly means it’s always in high demand for residential and commercial applications. Spray Foam Insulation is critical for solving our nation’s energy challenges because it dramatically reduces the energy needed to heat and cool our homes and offices.
Manufacturers who mass-produce wood products use automated spray systems, allowing them to paint materials at a very high rate with a minimum of personnel. Automated spray systems usually incorporate a paint-saving system which recovers paint not applied to the products. Commonly, linear spray systems are for products which are lying flat on a conveyor belt and then fed into a linear spray system, where automated spray guns are stationed above. When the material is directly below the guns, the guns begin to paint the material. Materials consist of lineal parts usually less than 12 inches (30 cm) wide, such as window frames, wood moulding, baseboard, casing, trim stock, and any other material that is simple in design. These machines are commonly used to apply stain, sealer, and lacquer. They can apply water- or solvent-based coatings. In recent years ultraviolet-cured coatings have become commonplace in profile finishing, and there are machines particularly suited to this type of coating.

Find spray foam contractors, suppliers, equipment, news, and technical information about spray foam insulation, foam roofing, and protective coatings. If you are a homeowner, builder/architect, or interested to get into the spray foam business, we have set-up special areas just for you. Check out our information packed Spray Foam Guides to learn more.
I installed Prodex in my 40'x40'x14' Steel garage when I bought the building it came with the 4" thick 6' wide white vinyl that was hard to work with because of it's weight and bulkiness. The weather was rainy and it was just my wife and I installing the insulation and steel sheeting. Trying to find something easier to work with I found your product I ordered enough to line the entire garage it was grate to work with. When the garage door company cam to install the garage doors on January 02/2010 the temperature outside was 10 degrees and windy. After they had the door tracks fastened enough to hold the doors in place they light there portable gas salamander I was impressed with how quickly it warmed to 40 degrees and healed the heat after they turned it off.

Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Spray Coating
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating Services
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies.
The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit. 
Tools: Ames® premium elastomeric roof coatings can be applied with a paint brush, a push broom, a paint roller or a commercial/industrial airless sprayer. In addition, you may need Ames® Peel & Stick™ Seam Tape, a pair of scissors and utility knife. For larger commercial jobs, we recommend a commercial/industrial airless sprayer. Call 888-345-0809 with questions or click here for sprayer specifications.
There have been a few mentions of intumescent coatingsabove, and it would be helpful to elaborate on them. Intumescent coating is a type of paint that will bubble when it is exposed to heat or flames. The bubbles act as a barrier that is relatively flame resistant. The bubbled coating delays the ignition of the spray foaminsulation. Because of this, intumescent coatings have become more common in building and construction.

There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary.


One application of spray painting is graffiti. The introduction of inexpensive and portable aerosol paint has been a boon to this art form, which has spread all over the world. Spray painting has also been used in fine art. Jules Olitski, Dan Christensen, Peter Reginato, Sir Anthony Caro, and Jean-Michel Basquiat have used airbrushes, for both painting and sculpture.

This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers. Spray Coating
×