Personal protective equipment (PPE) use: PPE must be used when handling spray paint materials, particularly PPE that offers protection to the skin. Some of the essential personal protective equipment are overalls with a hood, protective goggles for the eyes, half-mask respirators, and single use nitrile gloves. One of the most essential types of PPE is respiratory protective equipment (RPE). Nevertheless, basic RPE does not offer ample protection from the negative effects of isocyanates in human tissue. Paint products containing isocyanates must be handled while donning an air-fed RPE that has a 20 or higher APF (assigned protection factor). Air-fed respiratory protective equipment needs extra attention since they provide breathable air to the user. When in use, measures must be implemented to prevent contamination of the air supply since there is a risk of harmful substances entering the intake valve if it is not positioned outside of the spray area.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating Services
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Insulation Spray Coating
Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building.
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary.
I ordered a 5 gallon pail of WHITE  silicone roofing to use on my 3 season porch roof. I pressure washed and scrubbed the existing roof clean. When the product came it was not white as shown on the invoice, it was tan. After all of the time I spent cleaning and being that i travel for work, i did not have time to send it back and get the WHITE I had ordered. I applied two full coats of the tan and it went on well and looks good. Other that the color I am satisfied so far. I will likely not purchase from  Roof Coating Supply company again as they did not even respond to my complaint about the color. Spray Coating
At Praxair Surface Technologies, it’s our goal to help you get more protection, more customization and more performance from your parts. To do that, we work with you to select or develop coatings based on your operating environment and production requirements. Then we combine advanced preparation services, the right application technology and post-coating operations to create optimal coating performance for any component.
GacoRoof 100% Silicone Roof Coating creates a seamless membrane to seal and repair existing roofs and permanently protect against leaks, permanent ponding water and the damaging effects of severe weather. GacoRoof is available in several colors to enhance the aesthetics of any roof. Ideal for use on flat and sloped roofs including, but not limited to, large and small buildings, homes, garages and patio covers, sheds and barns, mobile homes, RVs and more.
Copyright © 2019 thereviewgurus.com. All rights reserved. As an Amazon Associate I earn from qualifying purchases. thereviewgurus.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. All prices on this site may change and those considered valid are displayed on Amazon.com.We also use third party advertising services to display advertisements on thereviewgurus.com, such as Google through the Google AdSense program. Some or all of those advertising services may use technology such as cookies and web beacons when they advertise on our site, which will send these advertisers information about your visit including your IP address, your ISP, the browser you used to visit our site, and in some cases, whether you have Flash installed. This is generally used for geotargeting purposes.Important Disclaimer: The information contained on thereviewgurus.com is intended for informational and educational purposes only. Any statements made on this website have not been evaluated by the FDA and any information or products discussed are not intended to diagnose, cure, treat or prevent any disease or illness. Please consult a healthcare practitioner before making changes to your diet or taking supplements that may interfere with medications.
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.   Spray Coating Services
Personal protective equipment (PPE) use: PPE must be used when handling spray paint materials, particularly PPE that offers protection to the skin. Some of the essential personal protective equipment are overalls with a hood, protective goggles for the eyes, half-mask respirators, and single use nitrile gloves. One of the most essential types of PPE is respiratory protective equipment (RPE). Nevertheless, basic RPE does not offer ample protection from the negative effects of isocyanates in human tissue. Paint products containing isocyanates must be handled while donning an air-fed RPE that has a 20 or higher APF (assigned protection factor). Air-fed respiratory protective equipment needs extra attention since they provide breathable air to the user. When in use, measures must be implemented to prevent contamination of the air supply since there is a risk of harmful substances entering the intake valve if it is not positioned outside of the spray area.
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Coating Services

I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store.
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments.
RE: my June 12 post...We went ahead and had the attic sprayed with a Soy-based product. Stayed in a hotel for 3 nites. Still smelled a little bad but that's gone away over time. I'm very glad we didn't use the other foam as even that much outgassing of a petrochemical could have sent my wife to the hospital. Unfortunately, the spray crew didn't speak English(at least not to me) and were kinda lazy, so they ended up spraying over some can fixtures from the kitchen below that were not insulation-contact rated. So I hired an electrician to come out, pull down the cans, pull out what he thought was an appropriate amount of foam to create a big enough air space and then re-install the cans. I billed the firm for the electrician plus an extra night we had to stay in the hotel and they paid, no questions asked. Guess they knew they had screwed up.   Spray Coating Services
HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1] Spray Coating

To see if ShippingPass is right for you, try a 30-day free trial. Also, with ShippingPass, there is no need to worry about commitment. If you decide you want to discontinue the service, you can cancel your subscription at any time. No matter what your shipping needs, Walmart's got you covered. Sign up for ShippingPass so you can shop more, save money and live better. Spray Coating Services


Spray painting poses health hazards that affect the respiratory, nervous, and circulatory systems. Similarly, using solvents to clean one's hands of paint marks and residue may cause skin irritation or even more serious issues since many are carcinogenic or neurotoxic. There are risks involved in working with substances such as paint and thinner, which contain compounds that are potentially harmful to health, or even fatal.[9]
I've used P&S BeadMaker, Meguiars Express Wax, Carnuba Wax, CMX and most recently Meguiars Hybrid Wax. To tell you the truth, if you're a gloss and slick addict, it really boils down to how well you prep your car. Wash, clay bar, compund, and polish. IPA wipe down. Anything else you put on after will highlight the shine you prepped with all the pre-work.
Blocking heat buildup is a complicated task. Heat comes in three forms: ultra-violet (UV), visible light, and infrared (IR). A quality ceramic coating will block all three, especially IR, which is responsible for roughly 57 percent of heat load on a building. “Some ceramic paints claim to block all heat caused by UV,” says Pritchett, “but UV only accounts for three percent of heat load on a building.”
E/M Coating Services has over 40 years of experience in applying critical tolerance coatings, and is a pioneer in the development and application of solid film lubricant (SFL) coatings. With its network of five U.S. facilities, E/M Coating Services is the largest applicator of solid film lubricant coatings in North America. Additional facilities in Evesham, U.K.; Unna, Germany and Tianjin & Suzhou, China apply a broad range of SFL and other coatings to steel, titanium and aluminum substrates. Spray Coating Services

Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.

Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Coating Services
I guess I'm saying all of these products are good, they will complement the work you do on your car if you're willing to put the time into it. And it will make it easier to maintain the next time you wash your car. If you don't clay and polish your car, don't expect super slick results. If you put the work into it, when you spray the car down with water, use a soap wash, rinseless wash, it will still shiny after you put any product on it! Don't get caught up in the SIO2 hype, just spend what you're willing to pay for the product. You'll be happy with any product.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response. 
While intumescent coating can be used instead of an ignition barrier or thermal barrier in some cases, the coating itself is not technically either. It does prevent or slow fires, so it has been approved to be used in conjunction with spray foaminsulation as an alternate assembly. The fact that it qualifies as an alternate assembly means that it can be used instead of a thermal barrier or ignition barrier.
Consumers should be careful to distinguish between purely reflective coatings and true insulating coatings. Reflective coatings only perform when clean and will not block all forms of heat, but a coating with insulative and reflective qualities will block more than one form of heat. “SuperTherm uses four ceramic compounds to block short-wave radiation, IR, and to block the conductivity of heat through the surface,” claims Pritchett. “It’s not just a reflective coating.” Insulation Spray Coating

As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine.


There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary. Insulation Spray Coating

You are driven and seize every opportunity to make a difference. At PPG Coatings Services, we are always seeking people who are committed to working hard and delivering world-class customer satisfaction. We understand that customer success means personal success, and provide career opportunities that help motivated people achieve their goals. Ready to learn more? Call 866-806-4018. Insulation Spray Coating
RE: my June 12 post...We went ahead and had the attic sprayed with a Soy-based product. Stayed in a hotel for 3 nites. Still smelled a little bad but that's gone away over time. I'm very glad we didn't use the other foam as even that much outgassing of a petrochemical could have sent my wife to the hospital. Unfortunately, the spray crew didn't speak English(at least not to me) and were kinda lazy, so they ended up spraying over some can fixtures from the kitchen below that were not insulation-contact rated. So I hired an electrician to come out, pull down the cans, pull out what he thought was an appropriate amount of foam to create a big enough air space and then re-install the cans. I billed the firm for the electrician plus an extra night we had to stay in the hotel and they paid, no questions asked. Guess they knew they had screwed up.   Spray Coating Services
One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up. Spray Coating Services
I applied CMX on my wife's car and my car and had odd results. See pic. I ended up with little white beads that formed when I sprayed CMX on car, wiped it to a haze, but not completely off. After about 2 minutes I then began to wipe CMX until the haze was gone. However, oddly, after letting the product dry (but not yet wiping completely off) it began to form white little beads (possibly residual). What a pain as these beads landed in all the window crevices, etc. It's like when you have a bad wax that leaves dust. I had to use a can of compressed air to wipe the bead out of the crevices. I was thinking that allowing it to haze would allow CMX to bond to the paint better. After getting the beads cleaned up I tested again and spray CMX on, then wiped completely dry. No beads. Coating Services
In recent years, there has been a significant rise in the use of spray foam insulation in construction. Spray foam insulation varies from traditional insulation, such as fiberglass, in many respects. Fiberglass insulation is typically much cheaper than spray foam insulation; however, it is also less effective at insulating your home. Additionally, spray foaminsulation requires professional installation. Though spray foam insulation is on the rise, fiberglass is still the most common form of home insulation used today.

Chris M.: Yes, I meant to mention in the article that this applies to both open cell (a.k.a. low density or 1/2 pound SPF) and closed cell (a.k.a. medium density or 2 pound SPF). Foam board insulation also needs to meet the requirements for thermal and ignition barriers, and some products, like Dow Thermax, have gotten approval to be left exposed. 
Charles: That photo is closed-cell SPF, and it's not sprayed perfectly uniformly. As long as it has the minimum thickness required (3" on a ceiling here in the Atlanta area), it should be fine. I've discussed some problems with SPF installations in the articles listed in the Related Articles section above. This photo is from about 10 years ago, though, and has no ignition barrier.  
Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close Insulation Spray Coating
Ever wonder why it's so hot and wet inside a metal building that has spray foam insulation, in the summer and so cold and wet in winter? The metal skin magnifies the heat of the summer and frigid temperatures of the winter. Metal is a very good conductor of heat and cold. In hot weather, metal framing and sheeting rapidly radiate the sun's heat into a building. In cold weather it rapidly releases the heat out of your building. When warm air comes in contact with the cool metal sheet, condensation occurs. 

Heat Shield™ EPX-H2O is a complete thermal barrier insulation system for pipes, tanks, and other industrial equipment and can provide 100% insulation coverage of all odd-shaped configurations – no more expensive insulation jackets or insulated covers needed. This next generation heat insulating coating has you covered for all types of directives – energy savings, safe touch for employee safety, heat radiation reduction, and asset protection from chemicals and corrosion. Don’t leave uninsulated areas in your pipe and tank insulation system that will lead to heat and energy loss. Instead use an easy spray-on solution that can coat, protect, and insulate your entire heat process system, including valves, pipes, tanks, boilers, heat exchangers, and more. Synavax™ thermal insulating and protective coating is a technology you can trust to perform consistently for 10 years or more. Spray Coating
The standard prescriptive material that can be used as a thermal barrier is 1/2" gypsum board (a.k.a. drywall or sheetrock). Anything else has to be approved as an 'equivalent thermal barrier' by undergoing tests for temperature transmission and fire integrity. In some cases, however, you need only one test. According to the Spray Polyurethane Foam Alliance (SPFA), "Under specific conditions, the temperature transmission test can be waived if approved by building code authorities on the basis of large-scale fire testing representing actual uses." (See their pdf document, Thermal and Ignition Barriers For The SPF Industry.)

For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Insulation Spray Coating
Personal protective equipment (PPE) use: PPE must be used when handling spray paint materials, particularly PPE that offers protection to the skin. Some of the essential personal protective equipment are overalls with a hood, protective goggles for the eyes, half-mask respirators, and single use nitrile gloves. One of the most essential types of PPE is respiratory protective equipment (RPE). Nevertheless, basic RPE does not offer ample protection from the negative effects of isocyanates in human tissue. Paint products containing isocyanates must be handled while donning an air-fed RPE that has a 20 or higher APF (assigned protection factor). Air-fed respiratory protective equipment needs extra attention since they provide breathable air to the user. When in use, measures must be implemented to prevent contamination of the air supply since there is a risk of harmful substances entering the intake valve if it is not positioned outside of the spray area.
When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof. Spray Coating Services
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Insulation Spray Coating
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating Services

Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor. Spray Coating Services
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article.
You are eligible for a full refund if no ShippingPass-eligible orders have been placed. You cannot receive a refund if you have placed a ShippingPass-eligible order. In this case, the Customer Care team will remove your account from auto-renewal to ensure you are not charged for an additional year and you can continue to use the subscription until the end of your subscription term. Coating Services
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can.

Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. Spray Coating Services
once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly. Coating Services
The Rubberseal creates a coat that can efficiently reflect heat off the roofs of buildings. It is Energy Star rated, which means it’s friendly to the environment.The spread rate of this product is 60 square feet per gallon at 20 imperial mils. It dries in 2 hours but takes 72 hours to get fully cured. Check the weather forecast before you apply it. Spray Coating Services

Thermal spraying need not be a dangerous process, if the equipment is treated with care, and correct spraying practices are followed. As with any industrial process, there are a number of hazards, of which the operator should be aware, and against which specific precautions should be taken. Ideally, equipment should be operated automatically, in enclosures specially designed to extract fumes, reduce noise levels, and prevent direct viewing of the spraying head. Such techniques will also produce coatings that are more consistent. There are occasions when the type of components being treated, or their low production levels, requires manual equipment operation. Under these conditions, a number of hazards, peculiar to thermal spraying, are experienced, in addition to those commonly encountered in production or processing industries.[6]
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc.
Thermal spraying need not be a dangerous process, if the equipment is treated with care, and correct spraying practices are followed. As with any industrial process, there are a number of hazards, of which the operator should be aware, and against which specific precautions should be taken. Ideally, equipment should be operated automatically, in enclosures specially designed to extract fumes, reduce noise levels, and prevent direct viewing of the spraying head. Such techniques will also produce coatings that are more consistent. There are occasions when the type of components being treated, or their low production levels, requires manual equipment operation. Under these conditions, a number of hazards, peculiar to thermal spraying, are experienced, in addition to those commonly encountered in production or processing industries.[6]
These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness. Insulation Spray Coating
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response.  Spray Coating Services
This is where things get a little tricky. If a home has spray foam insulation in an attic or crawl space, the building code requires using materials or assemblies that offer some fire resistance but not as much as is required for a thermal barrier. If you've got spray foam insulation in an attic, for example, it's probably already separated from the living space by a thermal barrier. Most ceilings are made of 1/2" drywall. But the spray foam is still exposed to the attic and needs an ignition barrier.
These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness.
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Spray Coating
×