Fiberglass is also rated in terms of thickness. “Six inches of fiberglass insulation might get an R-19 rating,” says Pritchett, “but how many builders will cram that six inches of insulation into four inches of stud wall? That R-19 rating doesn’t account for compression of the product.” SuperTherm achieves an R-19 rating with one coat applied, and a rating of R-28.5 when the surface is coated on the exterior and interior.
Whether you work on frame-up restorations in your garage, or projects like refinishing wheels, interior upgrades or maintaining the appearance of your everyday ride, Dupli-Color wants to be there with you. We have a heritage of providing only the best in automotive products since 1938, when we first started selling touch-up paint. This marked the beginning of “innovative firsts” which continues today with the automotive aftermarket’s largest array of DIY paints, primers and coatings. Spray Coating Services

Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Insulation Spray Coating
Combustion spraying equipment produces an intense flame, which may have a peak temperature more than 3,100 °C, and is very bright. Electric arc spraying produces ultra-violet light, which may damage delicate body tissues.Plasma also generates quite a lot of UV radiation, easily burning exposed skin and can also cause "flash burn" to the eyes. Spray booths, and enclosures, should be fitted with ultra-violet absorbent dark glass. Where this is not possible, operators, and others in the vicinity should wear protective goggles containing BS grade 6 green glass. Opaque screens should be placed around spraying areas. The nozzle of an arc pistol should never be viewed directly, unless it is certain that no power is available to the equipment.[6]
Open cell spray foams are less common and have a lower resistance to heat flow than closed cell spray does. Open cell spray foaminsulation expands when it is applied, which allows it to be installed in hard to reach areas, such as small wall and ceiling cavities. Open-cell spray foam is typically cheaper than closed cell foam is, but it is more permeable and vulnerable to fire hazards. Spray Coating Services

Chris M.: Yes, I meant to mention in the article that this applies to both open cell (a.k.a. low density or 1/2 pound SPF) and closed cell (a.k.a. medium density or 2 pound SPF). Foam board insulation also needs to meet the requirements for thermal and ignition barriers, and some products, like Dow Thermax, have gotten approval to be left exposed. 
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response.  Spray Coating Services
Due to a wide range of nozzle shapes and sizes, the consistency of the paint can be varied. The shape of the workpiece and the desired paint consistency and pattern are important factors when choosing a nozzle. The three most common nozzles are the full cone, hollow cone, and flat stream.[6] There are two types of air-gun spraying processes. In a manual operation method the air-gun sprayer is held by a skilled operator, about 6 to 10 inches (15–25 cm) from the object, and moved back and forth over the surface, each stroke overlapping the previous to ensure a continuous coat.[7] In an automatic process the gun head is attached to a mounting block and delivers the stream of paint from that position. The object being painted is usually placed on rollers or a turntable to ensure overall equal coverage of all sides. Coating Services

With all good DIY projects, you need to start with quality products to get the job done right. Krylon spray paints can cover anything from plastic and metal to cement and more. Use Krylon blue spray paint, Krylon green spray paint or Krylon yellow spray paint in a stained-glass finish to make a new table centerpiece. Krylon red spray paint, Krylon purple spray paint and Krylon orange spray paint can revitalize old patio décor into a vibrant outdoor space. Breathe new life into patio planters with Krylon brown spray paint. It’s easy to stay on trend with Krylon pink spray paint or get creative with Krylon metallic spray paint. With all these colors, the possibilities are endless. For projects that need just the basics, Krylon white spray paint, Krylon black spray paint and Krylon gray spray paint can help you tackle any job.


Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code. Spray Coating


The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important.
Hydraulic and air-powered airless pumps have linear motors that require a hydraulic pump or an air compressor, which can be electric or gasoline powered, although an air compressor is usually diesel powered for mobile use or electric for fixed installations. Some airless units have the hydraulic pump and its motor, built onto the same chassis as the paint pump. Spray Coating

Mascoat is a great alternative to conventional insulation materials, including cellular glass, perlite, mineral wool, fiberglass, urethane & closed cell foam and calcium silicate. Mascoat coatings are lighter than traditional insulation, reducing bulk in your structure. Mascoat also requires much less maintenance than conventional insulation, which can ultimately save you time and money. Want to get started with Mascoat? Request more information today. Insulation Spray Coating
Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building.
Thermal spraying need not be a dangerous process, if the equipment is treated with care, and correct spraying practices are followed. As with any industrial process, there are a number of hazards, of which the operator should be aware, and against which specific precautions should be taken. Ideally, equipment should be operated automatically, in enclosures specially designed to extract fumes, reduce noise levels, and prevent direct viewing of the spraying head. Such techniques will also produce coatings that are more consistent. There are occasions when the type of components being treated, or their low production levels, requires manual equipment operation. Under these conditions, a number of hazards, peculiar to thermal spraying, are experienced, in addition to those commonly encountered in production or processing industries.[6] Insulation Spray Coating
This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly. Spray Coating Services
If you're plagued with quality problems caused by uneven application of coatings or waste of costly coatings due to over-application, take a close look at our products for precision coating. You will find a wide range of nozzles, standard and heated spray headers and automated spray systems to apply all types of coatings – including thick slurries, chocolate, viscous oils and more – uniformly with minimal waste. Spray Coating

You like to make the tough call and enjoy having the authority to make decisions in the best interests of your customers. At PPG Coatings Services, we value those traits because our industry is constantly changing. In our business, you can't always wait for a decision, a change or a result. We constantly invest in our business, but we also invest in you, providing the skills, technical knowledge and independence you need to create loyal, satisfied and successful customers. Insulation Spray Coating
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)

The second type of barrier that prevents insulation from catching fire is called the ignition barrier. Ignition barriers are a lower standard to meet than a thermal barrier. Additionally, several different materials can meet the definition of an ignition barrier. Now that we have established the code jargon for spray foam barriers, we can look at each type in detail.
I've had concerns with foam in walls with only 2-3" and the resulting air space & convective currents. spray foam for walls is not one of my recommendations to my clients. instead foam sheathing to exterior of walls caulked,taped & sealed. conventional insulation & air tight drywall approach. a better and affordable wall with no extremely long payback like spray foam in walls.  Insulation Spray Coating
FIRESHELL® (F10E) is a proprietary non-flammable, intumescing (expands up to 2000%) interior coating that provides oxygen starvation to fire. It is a non-toxic, water based, drain safe, no fuming GREEN product. FIRESHELL® passes full scale room corner over foam, NFPA 286 and E84 class A certified. Meets requirements for 15 minute thermal barrier. It is a water-based one part coating system that comes white but can be tinted different colors. This coating can be top-coated with either latex or oil based coating.

The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit.  Coating Services
Blocking heat buildup is a complicated task. Heat comes in three forms: ultra-violet (UV), visible light, and infrared (IR). A quality ceramic coating will block all three, especially IR, which is responsible for roughly 57 percent of heat load on a building. “Some ceramic paints claim to block all heat caused by UV,” says Pritchett, “but UV only accounts for three percent of heat load on a building.”
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) Spray Coating
Yes, you're right that all of the problems mentioned above are related to the installer. I didn't try to hide that and even used the word 'installer' in two of the four headings. I can see how you'd think that the title is misleading, but in the end you can't separate spray foam insulation from its installation. Some people have the mistaken impression that if you get spray foam in your house, your home will outperform all others. My point here is that that's not true.

Combustion spraying guns use oxygen and fuel gases. The fuel gases are potentially explosive. In particular, acetylene may only be used under approved conditions. Oxygen, while not explosive, will sustain combustion, and many materials will spontaneously ignite, if excessive oxygen levels are present. Care must be taken to avoid leakage, and to isolate oxygen and fuel gas supplies, when not in use.[6] Spray Coating Services
Combustion spraying guns use oxygen and fuel gases. The fuel gases are potentially explosive. In particular, acetylene may only be used under approved conditions. Oxygen, while not explosive, will sustain combustion, and many materials will spontaneously ignite, if excessive oxygen levels are present. Care must be taken to avoid leakage, and to isolate oxygen and fuel gas supplies, when not in use.[6] Spray Coating Services
The Rubberseal creates a coat that can efficiently reflect heat off the roofs of buildings. It is Energy Star rated, which means it’s friendly to the environment.The spread rate of this product is 60 square feet per gallon at 20 imperial mils. It dries in 2 hours but takes 72 hours to get fully cured. Check the weather forecast before you apply it.

I ordered a 5 gallon pail of WHITE  silicone roofing to use on my 3 season porch roof. I pressure washed and scrubbed the existing roof clean. When the product came it was not white as shown on the invoice, it was tan. After all of the time I spent cleaning and being that i travel for work, i did not have time to send it back and get the WHITE I had ordered. I applied two full coats of the tan and it went on well and looks good. Other that the color I am satisfied so far. I will likely not purchase from  Roof Coating Supply company again as they did not even respond to my complaint about the color.
When intumescent coatings are used with spray foaminsulation, they are specific to each insulation brand. You cannot use one intumescent coating with a brand that it was not intended for. If you do not use the properspray foaminsulation brand and intumescent coating combination, then your work will not technically be up to code. Additionally, it is important to keep in mind that intumescent coating can only be used as an ignition barrier alternative if it is being used in an attic or crawl space. And, even then, it can only be used if space is not used for storage and is accessible through a small hatch or door. Spray Coating
“Since most of mechanical heat is IR heat, ceramic coatings can be used to prevent heat loss from inside a building,” Pritchett says. A home interior coated in ceramic paint can therefore reduce energy costs due to heat loss in the colder months. “We estimate that a home can save up to 40 to 50 percent in energy costs using our product,” Pritchett says. Payback on a product like SuperTherm, which retails for about $100 per gallon, can come in as little as two years.
The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments. Spray Coating

During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Insulation Spray Coating
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Spray Coating
In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing. Coating Services
Spray foam insulation is becoming increasingly popular and replacing many traditional forms of insulation, such as fiberglass. When using a spray foam insulation, it is important to take the proper steps to ensure that it is flame resistant. While building code is frequently ambiguous, poorly worded, and poorly enforced, a builder should always take the proper safety precautions with spray foam insulation. Spray foam insulation typically needs either a thermal barrier or ignition barrier in order to satisfy building code requirements.
Hydraulic or air powered airless provide a more uniform pressure control since the paint piston moves at a constant speed except when it changes direction. In most direct drive piston pumps, the piston is crankshaft driven in which the piston will be constantly changing speed. The linear motors of hydraulic or compressed air drive pumps, are more efficient in converting engine power to material power, than crankshaft driven units. All types of paint can be painted by using airless method.
The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments.
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause:
In recent years, there has been a significant rise in the use of spray foam insulation in construction. Spray foam insulation varies from traditional insulation, such as fiberglass, in many respects. Fiberglass insulation is typically much cheaper than spray foam insulation; however, it is also less effective at insulating your home. Additionally, spray foaminsulation requires professional installation. Though spray foam insulation is on the rise, fiberglass is still the most common form of home insulation used today. Insulation Spray Coating
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
×