This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area.

Spray foam insulation is becoming increasingly popular and replacing many traditional forms of insulation, such as fiberglass. When using a spray foam insulation, it is important to take the proper steps to ensure that it is flame resistant. While building code is frequently ambiguous, poorly worded, and poorly enforced, a builder should always take the proper safety precautions with spray foam insulation. Spray foam insulation typically needs either a thermal barrier or ignition barrier in order to satisfy building code requirements.
I've had concerns with foam in walls with only 2-3" and the resulting air space & convective currents. spray foam for walls is not one of my recommendations to my clients. instead foam sheathing to exterior of walls caulked,taped & sealed. conventional insulation & air tight drywall approach. a better and affordable wall with no extremely long payback like spray foam in walls.  Spray Coating Services
When intumescent coatings are used with spray foaminsulation, they are specific to each insulation brand. You cannot use one intumescent coating with a brand that it was not intended for. If you do not use the properspray foaminsulation brand and intumescent coating combination, then your work will not technically be up to code. Additionally, it is important to keep in mind that intumescent coating can only be used as an ignition barrier alternative if it is being used in an attic or crawl space. And, even then, it can only be used if space is not used for storage and is accessible through a small hatch or door.
This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly.
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause:
The criterion for whether your crawl space or attic is occupied is often the size of the entrance. Entry to the crawl space or attic should be a small hatch or door, not a normal-sized door. Additionally, if you cannot get to whatever area you are insulating without cutting through a drywall layer, then you do not need to use an ignition barrier, because the drywall already serves the purpose of the thermal barrier. Spray Coating
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating

Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Spray Coating Services
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary. Spray Coating

Mass-produced material is loaded on a conveyor belt where it is fed into one of these flatline machines. Flatline machines are designed to specifically paint material that is less than 4 inches (10 cm) thick and complex in shape, for example a kitchen cabinet door or drawer front. Spray guns are aligned above the material and the guns are in motion in order to hit all the grooves of the material. The guns can be moved in a cycle, circle, or can be moved back and forth in order to apply paint evenly across the material. Flatline systems are typically large and can paint doors, kitchen cabinets, and other plastic or wooden products. Insulation Spray Coating

The detonation gun consists of a long water-cooled barrel with inlet valves for gases and powder. Oxygen and fuel (acetylene most common) are fed into the barrel along with a charge of powder. A spark is used to ignite the gas mixture, and the resulting detonation heats and accelerates the powder to supersonic velocity through the barrel. A pulse of nitrogen is used to purge the barrel after each detonation. This process is repeated many times a second. The high kinetic energy of the hot powder particles on impact with the substrate results in a buildup of a very dense and strong coating.


Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Spray Coating
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof? Insulation Spray Coating
The deposition efficiency is typically low for alloy powders, and the window of process parameters and suitable powder sizes is narrow. To accelerate powders to higher velocity, finer powders (<20 micrometers) are used. It is possible to accelerate powder particles to much higher velocity using a processing gas having high speed of sound (helium instead of nitrogen). However, helium is costly and its flow rate, and thus consumption, is higher. To improve acceleration capability, nitrogen gas is heated up to about 900 °C. As a result, deposition efficiency and tensile strength of deposits increase.[1] Spray Coating
These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness.
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary.

When intumescent coatings are used with spray foaminsulation, they are specific to each insulation brand. You cannot use one intumescent coating with a brand that it was not intended for. If you do not use the properspray foaminsulation brand and intumescent coating combination, then your work will not technically be up to code. Additionally, it is important to keep in mind that intumescent coating can only be used as an ignition barrier alternative if it is being used in an attic or crawl space. And, even then, it can only be used if space is not used for storage and is accessible through a small hatch or door. Spray Coating

You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Coating Services
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution.

Most electric powered airless pumps have an electric motor connected through a gear train to the paint piston pump. Pressure is achieved by stopping and starting the motor via a pressure sensor (also called a transducer); in more advanced units, this is done by digital control in which the speed of the motor varies with the demand and the difference from the pressure set-point, resulting in a very good pressure control. Some direct drive piston pumps are driven by a gasoline engine with pressure control via an electric clutch. In electric diaphragm pumps, the motor drives a hydraulic piston pump that transmits the oil displaced by the piston, to move the diaphragm. Coating Services
E/M Coating Services has over 40 years of experience in applying critical tolerance coatings, and is a pioneer in the development and application of solid film lubricant (SFL) coatings. With its network of five U.S. facilities, E/M Coating Services is the largest applicator of solid film lubricant coatings in North America. Additional facilities in Evesham, U.K.; Unna, Germany and Tianjin & Suzhou, China apply a broad range of SFL and other coatings to steel, titanium and aluminum substrates.
This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area.
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  
Most electric powered airless pumps have an electric motor connected through a gear train to the paint piston pump. Pressure is achieved by stopping and starting the motor via a pressure sensor (also called a transducer); in more advanced units, this is done by digital control in which the speed of the motor varies with the demand and the difference from the pressure set-point, resulting in a very good pressure control. Some direct drive piston pumps are driven by a gasoline engine with pressure control via an electric clutch. In electric diaphragm pumps, the motor drives a hydraulic piston pump that transmits the oil displaced by the piston, to move the diaphragm. Coating Services
In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing.
Estimated Coverage: Standard product coverage on a smooth surface for Ames® Super Primer™ is 200 sq. ft. per gallon per coat and the product coverage rate for Ames® Maximum Stretch® and Ames® Iron Coat® is 100 sq. ft. per gallon per coat. Rough or uneven surfaces may require additional product. More than one coat of Ames® Maximum Stretch® or Ames® Iron Coat® is recommended. More coats equal longer life.
As an Amazon Associate I earn from qualifying purchases. thereviewgurus.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. All prices on this site may change and those considered valid are displayed on Amazon.com. Spray Coating Services
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.

I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store. Coating Services
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building. Insulation Spray Coating
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Spray Coating
×