Since our founding in 1973, Dal-Bac Manufacturing Co., Inc. has grown and expanded to become one of the premier providers of coating services to customers in a diverse range of industries. We are capable of applying both solvent and water-borne coatings to a wide variety of substrates, including fabrics, films, foams, and papers. Our capabilities include both knife-over-roll and Meyer rod coating methods for roll goods up to 61” in width. With our custom built equipment, we process materials accurately and cost-effectively. Coating Services
Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed. Coating Services
Surface Preparation (Residential & Commercial): Pressure wash when possible using pure water. Be sure the surface is clean and completely dry before the application of the coating. Read all label instructions before beginning. Surface must be in savable condition, clean and dry, and should have proper drainage. Always run a test patch first in an inconspicuous area, to ensure that proper adhesion and drying occurs and the product works to your satisfaction. Apply Ames® Peel & Stick™ adhesive seam tape and tape on all badly deteriorated fasteners, rubber washers, joints, seams and around vents. Do not use any soaps or detergents to clean the surface.
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. Spray Coating Services
Weather & Drying Guidelines: Ames® Super Primer™, Maximum-Stretch® and Iron Coat® is best applied between 50° to 90° F (10° to 32° C) on warm dry surfaces. Apply when the streets are dry, the sun is in the sky and no inclement weather is forecast. Starts to dry in about 2-8 hours, depending on thickness of application and weather. It is recommended to allow a minimum of 24 hours between coats with no rain in the forecast and no freezing temperatures. Low temperatures, high humidity and evening and morning dew will require increased drying/curing time. Do not apply after 2pm for best drying. The earlier you can put it on, the better. Make sure any morning dew is completely dried off before proceeding. Spray Coating
The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.  

I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Insulation Spray Coating

Spray painting is a painting technique where a device sprays a coating (paint, ink, varnish, etc.) through the air onto a surface. The most common types employ compressed gas—usually air—to atomize and direct the paint particles. Spray guns evolved from airbrushes, and the two are usually distinguished by their size and the size of the spray pattern they produce. Airbrushes are hand-held and used instead of a brush for detailed work such as photo retouching, painting nails or fine art. Air gun spraying uses equipment that is generally larger. It is typically used for covering large surfaces with an even coating of liquid. Spray guns can be either automated or hand-held and have interchangeable heads to allow for different spray patterns. Single color aerosol paint cans are portable and easy to store.
Synavax™ thermal insulation coatings are the top choice for a wide variety of thermal insulating paint applications over equipment like pipes, pipelines, tanks, ovens, processing vessels, heat exchangers and more. Synavax™ patented industrial thermal insulation paint solves corrosion-under-insulation (CUI) by both insulating and preventing corrosion with a single product. Our thermal paint coatings are multipurpose spray or paint applied products that are simple to deploy.
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
×