These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness. Insulation Spray Coating
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
I applied this product on a rolled asphalt flat patio roof. It was over 90 degrees and I could not touch the roofing at all on the first coat. I was laying on layers of cardboard to apply the silicone under the gutters and then rolled the first coat. The next day I brought all the cardboard to apply the coating under the gutters. I accidentally touched the roof and it was cool‼️  I threw the cardboard off the roof, laid down to do the gutters and roll the second coat. I was amazed how well this sealed and cooled the patio. I am going to apply this to my other patio and covered parking which are metal. I can’t wait to apply for sealing and adding cooling to these areas. Roof Coating Supply answered all my question and they ship promptly - I had my order in 3 days. Thank you. Spray Coating
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think. Coating Services
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc. Insulation Spray Coating

When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof. Spray Coating Services


I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating
We highly recommend the Rubberseal as the best roof coating. It is waterproof and protective, while having less odor and volatile organic compounds. It would be perfect for those who do roof coating as a daily job.The Rubberseal is designed to provide a reliable seal for all types of waterproofing applications. It’s ideal for both home and industry uses.
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think. Spray Coating
Improve energy efficiency easily with our thermal barrier coatings that can be used on multiple surfaces types. Use as a stainless steel coating, steel insulation coating, copper thermal coat, galvanized coating, heat insulation coating for aluminum, and multiple other surfaces to improve energy efficiency, lower surface temperatures, reduce heat expelled into the environment from hot equipment, and stop rust and CUI.
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Spray Coating Services
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. Coating Services

There have been a few mentions of intumescent coatingsabove, and it would be helpful to elaborate on them. Intumescent coating is a type of paint that will bubble when it is exposed to heat or flames. The bubbles act as a barrier that is relatively flame resistant. The bubbled coating delays the ignition of the spray foaminsulation. Because of this, intumescent coatings have become more common in building and construction. Insulation Spray Coating
These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness. Spray Coating
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
Mass-produced material is loaded on a conveyor belt where it is fed into one of these flatline machines. Flatline machines are designed to specifically paint material that is less than 4 inches (10 cm) thick and complex in shape, for example a kitchen cabinet door or drawer front. Spray guns are aligned above the material and the guns are in motion in order to hit all the grooves of the material. The guns can be moved in a cycle, circle, or can be moved back and forth in order to apply paint evenly across the material. Flatline systems are typically large and can paint doors, kitchen cabinets, and other plastic or wooden products. Insulation Spray Coating
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level.

Fiberglass is also rated in terms of thickness. “Six inches of fiberglass insulation might get an R-19 rating,” says Pritchett, “but how many builders will cram that six inches of insulation into four inches of stud wall? That R-19 rating doesn’t account for compression of the product.” SuperTherm achieves an R-19 rating with one coat applied, and a rating of R-28.5 when the surface is coated on the exterior and interior.


Electrostatic painting was first patented in the U.S. by Harold Ransburg in the late 1940s. Harold Ransburg founded Ransburg Electrostatic Equipment and discovered that electrostatic spray painting was an immediate success as manufacturers quickly perceived the substantial materials savings that could be achieved. In electrostatic spray painting or powder coating, the atomized particles are made to be electrically charged, thereby repelling each other and spreading themselves evenly as they exit the spray nozzle. The object being painted is charged oppositely or grounded. The paint is then attracted to the object giving a more even coat than wet spray painting, and also greatly increasing the percentage of paint that sticks to the object. This method also means that paint covers hard to reach areas. The whole may then be baked to properly attach the paint: the powder turns into a type of plastic. Car body panels and bike frames are two examples where electrostatic spray painting is often used. Coating Services
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Insulation Spray Coating

Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier. Spray Coating
×