The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Spray Coating Services
This is where things get a little tricky. If a home has spray foam insulation in an attic or crawl space, the building code requires using materials or assemblies that offer some fire resistance but not as much as is required for a thermal barrier. If you've got spray foam insulation in an attic, for example, it's probably already separated from the living space by a thermal barrier. Most ceilings are made of 1/2" drywall. But the spray foam is still exposed to the attic and needs an ignition barrier.

The Barrier product family is EPS foam under The Barrier product family is EPS foam under slab insulation and vapor retarder in a roll designed to insulate radiant heating projects from heat loss and retard moisture migration through concrete. The core of the product is made of flexible recyclable expanded polystyrene that provides excellent insulation characteristics that are ...  More + Product Details Close Coating Services

Mascoat's family of thermal insulating paint is guaranteed to have the coating you need for your application. Whether you have a boat with condensation issues or a factory that needs to keep energy costs low, Mascoat can help. Contact Mascoat today to learn more about our thermal insulation coatings and how a custom tailored solution can be made just for your application! Spray Coating


This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly. Spray Coating Services

Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed.
You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Coating Services

Yes, you're right that all of the problems mentioned above are related to the installer. I didn't try to hide that and even used the word 'installer' in two of the four headings. I can see how you'd think that the title is misleading, but in the end you can't separate spray foam insulation from its installation. Some people have the mistaken impression that if you get spray foam in your house, your home will outperform all others. My point here is that that's not true.


As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine. Coating Services


As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine.

Manufacturers who mass-produce wood products use automated spray systems, allowing them to paint materials at a very high rate with a minimum of personnel. Automated spray systems usually incorporate a paint-saving system which recovers paint not applied to the products. Commonly, linear spray systems are for products which are lying flat on a conveyor belt and then fed into a linear spray system, where automated spray guns are stationed above. When the material is directly below the guns, the guns begin to paint the material. Materials consist of lineal parts usually less than 12 inches (30 cm) wide, such as window frames, wood moulding, baseboard, casing, trim stock, and any other material that is simple in design. These machines are commonly used to apply stain, sealer, and lacquer. They can apply water- or solvent-based coatings. In recent years ultraviolet-cured coatings have become commonplace in profile finishing, and there are machines particularly suited to this type of coating.
Our elastomeric rubber coatings for metal roofs provide unmatched flexibility and resistance against harsh weather conditions. From tin roof sealant to corrugated and rusty metal roof sealants, our products are specially formulated for a wide variety of metal roof types. Check out our full selection of rubber coatings for metal roofs below, in addition to application instructions for the best results. Coating Services
Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code. Insulation Spray Coating

You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Insulation Spray Coating
When intumescent coatings are used with spray foaminsulation, they are specific to each insulation brand. You cannot use one intumescent coating with a brand that it was not intended for. If you do not use the properspray foaminsulation brand and intumescent coating combination, then your work will not technically be up to code. Additionally, it is important to keep in mind that intumescent coating can only be used as an ignition barrier alternative if it is being used in an attic or crawl space. And, even then, it can only be used if space is not used for storage and is accessible through a small hatch or door. Spray Coating
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
Thermal spraying can provide thick coatings (approx. thickness range is 20 microns to several mm, depending on the process and feedstock), over a large area at high deposition rate as compared to other coating processes such as electroplating, physical and chemical vapor deposition. Coating materials available for thermal spraying include metals, alloys, ceramics, plastics and composites. They are fed in powder or wire form, heated to a molten or semimolten state and accelerated towards substrates in the form of micrometer-size particles. Combustion or electrical arc discharge is usually used as the source of energy for thermal spraying. Resulting coatings are made by the accumulation of numerous sprayed particles. The surface may not heat up significantly, allowing the coating of flammable substances.
The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit.  Coating Services
The average price to cover 200 square feet with a foam insulation kit will run between $300 and $600 (about two to three kits). Inside these kits is something called Icynene, a foam made from two liquids that are heated and pushed through a gun on the can. When Icynene is released, it expands up to 100 times its size as it hits the surface area you're covering. These can contain a lot of gasses, making its installation a dangerous process. Even low-pressure sprayers can be harmful to homeowners' health.
This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area.
When do you need an ignition barrier? According to the IRC and IBC, an attic or crawl space needs an ignition barrier over the spray foam if the space can be accessed but will not be used for storage or auxiliary living space. You don't need an ignition barrier if the space cannot be accessed without cutting into it, if it is not connected to other spaces, and if it does not communicate with other spaces.
Spray painting is a painting technique where a device sprays a coating (paint, ink, varnish, etc.) through the air onto a surface. The most common types employ compressed gas—usually air—to atomize and direct the paint particles. Spray guns evolved from airbrushes, and the two are usually distinguished by their size and the size of the spray pattern they produce. Airbrushes are hand-held and used instead of a brush for detailed work such as photo retouching, painting nails or fine art. Air gun spraying uses equipment that is generally larger. It is typically used for covering large surfaces with an even coating of liquid. Spray guns can be either automated or hand-held and have interchangeable heads to allow for different spray patterns. Single color aerosol paint cans are portable and easy to store.
Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level.
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. Spray Coating Services
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
I've used P&S BeadMaker, Meguiars Express Wax, Carnuba Wax, CMX and most recently Meguiars Hybrid Wax. To tell you the truth, if you're a gloss and slick addict, it really boils down to how well you prep your car. Wash, clay bar, compund, and polish. IPA wipe down. Anything else you put on after will highlight the shine you prepped with all the pre-work. Spray Coating Services
Plasma transferred wire arc (PTWA) is another form of wire arc spray which deposits a coating on the internal surface of a cylinder, or on the external surface of a part of any geometry. It is predominantly known for its use in coating the cylinder bores of an engine, enabling the use of Aluminum engine blocks without the need for heavy cast iron sleeves. A single conductive wire is used as "feedstock" for the system. A supersonic plasma jet melts the wire, atomizes it and propels it onto the substrate. The plasma jet is formed by a transferred arc between a non-consumable cathode and the type of a wire. After atomization, forced air transports the stream of molten droplets onto the bore wall. The particles flatten when they impinge on the surface of the substrate, due to the high kinetic energy. The particles rapidly solidify upon contact. The stacked particles make up a high wear resistant coating. The PTWA thermal spray process utilizes a single wire as the feedstock material. All conductive wires up to and including 0.0625" (1.6mm) can be used as feedstock material, including "cored" wires. PTWA can be used to apply a coating to the wear surface of engine or transmission components to replace a bushing or bearing. For example, using PTWA to coat the bearing surface of a connecting rod offers a number of benefits including reductions in weight, cost, friction potential, and stress in the connecting rod. Spray Coating
×