Like HVLP, low volume low pressure (LVLP) spray guns also operate at a lower pressure (LP), but they use a low volume (LV) of air when compared to conventional and HVLP equipment. This is a further effort at increasing the transfer efficiency (amount of coating that ends up on the target surface) of spray guns, while decreasing the amount of compressed air consumption. Insulation Spray Coating

Prodex reflects 97% of the radiant energy (primary source of heat flow) that strikes it - Which also protects your animals from Black Globe Effect. Prodex also reflects back the heat inside your steel building. Each unit of radiant heat energy that is reflected away from your barn in the summer, and each unit that is reflected back during the winter, means less operation of your heating and air conditioning system - Less wear and tear on your equipment - Less money you pay in utility costs. Spray Coating
Prodex eliminates the moisture (condensation) from forming on the metal sheeting. It does it by making the temperature of the metal sheeting on the building approximately the same on the inside as the outside. When the heat or cold from outside comes through the metal skin it hits the outside aluminum facing of Prodex and is reflected back upwards through the underside of the metal sheeting. This process keeps the metal sheeting temperature consistent on both sides. In addition, the inside layer of aluminum in Prodex reflects away the heat (heater) or cold (air-conditioning) from inside the building, from getting to the metal skin. This also helps in preventing condensation. 
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof? Insulation Spray Coating

This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.  
Introducing Mothers CMX Ceramic Spray Coating, an affordable, user-friendly, professional grade, ultra-durable, super-hydrophobic protection formula. Just spray on and wipe off, with this game-changing SiO2 (Silicon Dioxide) and TiO2 (Titanium Dioxide) blend. This powerhouse combo provides ultra long-term protection from the elements and relentless water beading, without sacrificing true optical clarity, extreme depth and that signature ceramic glass-like liquid-gloss appearance. Use as a stand-alone product, or as a booster over your existing sealant or ceramic coating. Washing and caring for your vehicle has never been easier. Cures in 24 hours (do not get vehicle wet during curing period).
Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code.
Surface Preparation (Residential & Commercial): Pressure wash when possible using pure water. Be sure the surface is clean and completely dry before the application of the coating. Read all label instructions before beginning. Surface must be in savable condition, clean and dry, and should have proper drainage. Always run a test patch first in an inconspicuous area, to ensure that proper adhesion and drying occurs and the product works to your satisfaction. Apply Ames® Peel & Stick™ adhesive seam tape and tape on all badly deteriorated fasteners, rubber washers, joints, seams and around vents. Do not use any soaps or detergents to clean the surface. Spray Coating
The standard prescriptive material that can be used as a thermal barrier is 1/2" gypsum board (a.k.a. drywall or sheetrock). Anything else has to be approved as an 'equivalent thermal barrier' by undergoing tests for temperature transmission and fire integrity. In some cases, however, you need only one test. According to the Spray Polyurethane Foam Alliance (SPFA), "Under specific conditions, the temperature transmission test can be waived if approved by building code authorities on the basis of large-scale fire testing representing actual uses." (See their pdf document, Thermal and Ignition Barriers For The SPF Industry.) Spray Coating Services
Legend Coatings and Insulation values the integrity of our work. We have extensive training when it comes to spray application. All of our applicators at Legend are trained and certified to industry standards. We do not stand alone when it comes to the building science behind our systems . We work hand in hand with Certified HVAC Contractors, Architects and Building Officials to combine our experience and expertise to find the best possible system to suite your needs and maximize your investment. Spray Coating
Thermal spraying can provide thick coatings (approx. thickness range is 20 microns to several mm, depending on the process and feedstock), over a large area at high deposition rate as compared to other coating processes such as electroplating, physical and chemical vapor deposition. Coating materials available for thermal spraying include metals, alloys, ceramics, plastics and composites. They are fed in powder or wire form, heated to a molten or semimolten state and accelerated towards substrates in the form of micrometer-size particles. Combustion or electrical arc discharge is usually used as the source of energy for thermal spraying. Resulting coatings are made by the accumulation of numerous sprayed particles. The surface may not heat up significantly, allowing the coating of flammable substances. Spray Coating Services

This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly.

What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Spray Coating Services


Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable. Coating Services
Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
High volume low pressure (HVLP) is similar to a conventional spray gun using a compressor to supply the air, but the spray gun itself requires a lower pressure (LP). A higher volume (HV) of air is used to aerosolise and propel the paint at lower air pressure. The result is a higher proportion of paint reaching the target surface with reduced overspray, materials consumption, and air pollution. A regulator is often required so that the air pressure from a conventional compressor can be lowered for the HVLP spray gun. Alternatively a turbine unit (commonly containing a vacuum cleaner derived motor) can be used to propel the air without the need for an air line running to the compressor.
The Barrier product family is EPS foam under The Barrier product family is EPS foam under slab insulation and vapor retarder in a roll designed to insulate radiant heating projects from heat loss and retard moisture migration through concrete. The core of the product is made of flexible recyclable expanded polystyrene that provides excellent insulation characteristics that are ...  More + Product Details Close
You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done.
Vacuum plasma spraying (VPS) is a technology for etching and surface modification to create porous layers with high reproducibility and for cleaning and surface engineering of plastics, rubbers and natural fibers as well as for replacing CFCs for cleaning metal components. This surface engineering can improve properties such as frictional behavior, heat resistance, surface electrical conductivity, lubricity, cohesive strength of films, or dielectric constant, or it can make materials hydrophilic or hydrophobic.
Plasmas affect materials at an atomic level. Techniques like X-ray photoelectron spectroscopy and scanning electron microscopy are used for surface analysis to identify the processes required and to judge their effects. As a simple indication of surface energy, and hence adhesion or wettability, often a water droplet contact angle test is used. The lower the contact angle, the higher the surface energy and more hydrophilic the material is.
When you want to take any metal surface and make it more visually appealing, pay a visit to Xtreme Power Coating in Grand Prairie TX. Since 2003 we have provided powder coating services in Grand Prairie, TX that bring our customers’ furniture, iron fences and decorative metal pieces to life. Powder coat finishing transforms dull, worn out metal and gives it a bold, beautiful sheen that passersby won’t be able to help but notice. Prepare for compliments once your metal décor receives a powder coat finish make over. When it comes to powder coating in Grand Prairie, TX, no one else comes close to Xtreme Powder Coating. Insulation Spray Coating
I finally completed my 60" X 42" steel building using your insulation between the steel studs and the metal sheeting. I was amazed at the temperature difference. The metal is not allowed to adversely heat the building and the temperature is cooler than under a shade tree because of the breeze created within the door openings. The reflective foil also provides a tremendous amount of light reflection inside the building creating a very bright look inside. I am amazed and presently surprised that the thin foil actually worked so well.
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Coating Services

As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor. Coating Services


Hydraulic and air-powered airless pumps have linear motors that require a hydraulic pump or an air compressor, which can be electric or gasoline powered, although an air compressor is usually diesel powered for mobile use or electric for fixed installations. Some airless units have the hydraulic pump and its motor, built onto the same chassis as the paint pump. Spray Coating
×