I applied CMX on my wife's car and my car and had odd results. See pic. I ended up with little white beads that formed when I sprayed CMX on car, wiped it to a haze, but not completely off. After about 2 minutes I then began to wipe CMX until the haze was gone. However, oddly, after letting the product dry (but not yet wiping completely off) it began to form white little beads (possibly residual). What a pain as these beads landed in all the window crevices, etc. It's like when you have a bad wax that leaves dust. I had to use a can of compressed air to wipe the bead out of the crevices. I was thinking that allowing it to haze would allow CMX to bond to the paint better. After getting the beads cleaned up I tested again and spray CMX on, then wiped completely dry. No beads. Coating Services
Like HVLP, low volume low pressure (LVLP) spray guns also operate at a lower pressure (LP), but they use a low volume (LV) of air when compared to conventional and HVLP equipment. This is a further effort at increasing the transfer efficiency (amount of coating that ends up on the target surface) of spray guns, while decreasing the amount of compressed air consumption. Insulation Spray Coating
There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit. Coating Services
In cold spraying, particles are accelerated to very high speeds by the carrier gas forced through a converging–diverging de Laval type nozzle. Upon impact, solid particles with sufficient kinetic energy deform plastically and bond mechanically to the substrate to form a coating. The critical velocity needed to form bonding depends on the material's properties, powder size and temperature. Metals, polymers, ceramics, composite materials and nanocrystalline powders can be deposited using cold spraying.[4] Soft metals such as Cu and Al are best suited for cold spraying, but coating of other materials (W, Ta, Ti, MCrAlY, WC–Co, etc.) by cold spraying has been reported.[1] Insulation Spray Coating
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
I guess I'm saying all of these products are good, they will complement the work you do on your car if you're willing to put the time into it. And it will make it easier to maintain the next time you wash your car. If you don't clay and polish your car, don't expect super slick results. If you put the work into it, when you spray the car down with water, use a soap wash, rinseless wash, it will still shiny after you put any product on it! Don't get caught up in the SIO2 hype, just spend what you're willing to pay for the product. You'll be happy with any product. Coating Services
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) Spray Coating

With all good DIY projects, you need to start with quality products to get the job done right. Krylon spray paints can cover anything from plastic and metal to cement and more. Use Krylon blue spray paint, Krylon green spray paint or Krylon yellow spray paint in a stained-glass finish to make a new table centerpiece. Krylon red spray paint, Krylon purple spray paint and Krylon orange spray paint can revitalize old patio décor into a vibrant outdoor space. Breathe new life into patio planters with Krylon brown spray paint. It’s easy to stay on trend with Krylon pink spray paint or get creative with Krylon metallic spray paint. With all these colors, the possibilities are endless. For projects that need just the basics, Krylon white spray paint, Krylon black spray paint and Krylon gray spray paint can help you tackle any job.
The atomization of molten materials produces a large amount of dust and fumes made up of very fine particles (ca. 80–95% of the particles by number <100 nm).[8] Proper extraction facilities are vital, not only for personal safety, but to minimize entrapment of re-frozen particles in the sprayed coatings. The use of respirators, fitted with suitable filters, is strongly recommended, where equipment cannot be isolated.[8] Certain materials offer specific known hazards:[6] Insulation Spray Coating
The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments. Spray Coating
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Insulation Spray Coating
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  

New fire safety tests for intumescent coatings were created by code officials and the spray foam industry, and many manufacturers found their closed cell spray foams could pass the test without any intumescent coating. Some open cell spray foam can pass the fire tests without an intumescent coating, but most still require the coating. Approved closed cell spray foams do not need the ignition barriers discussed above, which can make the job easier for builders. Coating Services


Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close Spray Coating
Jennifer, I'm not an expert on the health effects of closed cell foam. A lot of people live in houses with closed cell foam and have no health problems from it, at least not short-term, acute problems. I do know of one person who had it removed from her crawl space because she was convinced it caused her dog to get sick, but I know only what she told me.  

HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1]
Kool Seal may be the best roof coating because it clings to your roof in all temperatures. It provides good protection against moisture, so it is suitable for humid areas.This product forms a thick barrier for the roof, which can reflect 90% of the sun’s rays. Whether in the hottest summer or in the coldest winter, this product maintains durable and protective.
The Rubberseal creates a coat that can efficiently reflect heat off the roofs of buildings. It is Energy Star rated, which means it’s friendly to the environment.The spread rate of this product is 60 square feet per gallon at 20 imperial mils. It dries in 2 hours but takes 72 hours to get fully cured. Check the weather forecast before you apply it. Spray Coating Services
Some ceramic coatings feature additional properties, like preventing moisture migration. Some structures see up to 25 percent of HVAC costs coming from dehumidification needs, but a ceramic coating can also bring savings through moisture management. Additional features can include mold and mildew control, sound attenuation properties, and fire resistance.

4 years ago I applied Gaco Roof, coats to an Office Building flat roof and have zero leaks since that time. This saved me $30,000 compared to having a new roof installed. The roof itself was only 7 years old when I applied Gaco Roof. but due to ponding water and harsh Florida heat and UV, the roof already looked shot and was leaking. I have now used Gaco Roof on 4 flat roofs to great results. I also tried big hardware store lower cost substitutes on 2 flat roofs. Those product utterly failed 1 to 2 years. Yes, I pressure washed my roofs clean before using Gaco Roof and followed their simple installation instructions. Excellent product. Insulation Spray Coating
New fire safety tests for intumescent coatings were created by code officials and the spray foam industry, and many manufacturers found their closed cell spray foams could pass the test without any intumescent coating. Some open cell spray foam can pass the fire tests without an intumescent coating, but most still require the coating. Approved closed cell spray foams do not need the ignition barriers discussed above, which can make the job easier for builders. Coating Services
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc.
Plasma transferred wire arc (PTWA) is another form of wire arc spray which deposits a coating on the internal surface of a cylinder, or on the external surface of a part of any geometry. It is predominantly known for its use in coating the cylinder bores of an engine, enabling the use of Aluminum engine blocks without the need for heavy cast iron sleeves. A single conductive wire is used as "feedstock" for the system. A supersonic plasma jet melts the wire, atomizes it and propels it onto the substrate. The plasma jet is formed by a transferred arc between a non-consumable cathode and the type of a wire. After atomization, forced air transports the stream of molten droplets onto the bore wall. The particles flatten when they impinge on the surface of the substrate, due to the high kinetic energy. The particles rapidly solidify upon contact. The stacked particles make up a high wear resistant coating. The PTWA thermal spray process utilizes a single wire as the feedstock material. All conductive wires up to and including 0.0625" (1.6mm) can be used as feedstock material, including "cored" wires. PTWA can be used to apply a coating to the wear surface of engine or transmission components to replace a bushing or bearing. For example, using PTWA to coat the bearing surface of a connecting rod offers a number of benefits including reductions in weight, cost, friction potential, and stress in the connecting rod.
There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit. Insulation Spray Coating
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Insulation Spray Coating
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend?

This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers. Coating Services
I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store. Spray Coating
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
×