Thermal spraying can provide thick coatings (approx. thickness range is 20 microns to several mm, depending on the process and feedstock), over a large area at high deposition rate as compared to other coating processes such as electroplating, physical and chemical vapor deposition. Coating materials available for thermal spraying include metals, alloys, ceramics, plastics and composites. They are fed in powder or wire form, heated to a molten or semimolten state and accelerated towards substrates in the form of micrometer-size particles. Combustion or electrical arc discharge is usually used as the source of energy for thermal spraying. Resulting coatings are made by the accumulation of numerous sprayed particles. The surface may not heat up significantly, allowing the coating of flammable substances. Spray Coating Services
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Coating Services
By heating the full-bodied paint to 60-80 °C, it is possible to apply a thicker coat. Originally the paint was recirculated, but as this caused bodying up, the system was changed to direct heating on line. Hot spraying was also used with Airless and Electrostatic Airless to decrease bounce-back. Two pack materials usually had premix before tip systems using dual pumps. Insulation Spray Coating
The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important.
I applied this product on a rolled asphalt flat patio roof. It was over 90 degrees and I could not touch the roofing at all on the first coat. I was laying on layers of cardboard to apply the silicone under the gutters and then rolled the first coat. The next day I brought all the cardboard to apply the coating under the gutters. I accidentally touched the roof and it was cool‼️  I threw the cardboard off the roof, laid down to do the gutters and roll the second coat. I was amazed how well this sealed and cooled the patio. I am going to apply this to my other patio and covered parking which are metal. I can’t wait to apply for sealing and adding cooling to these areas. Roof Coating Supply answered all my question and they ship promptly - I had my order in 3 days. Thank you. Spray Coating Services
Are you tired of dealing with insulation jackets or insulation covers that don’t fit? Spray-on thermal insulating coatings by Synavax™ fit any shape of equipment and do not require any exterior jacketing. You can spray apply this technology easily while equipment is in-service and our concentrated insulation coatings will work diligently for 5-10 years or more without degrading.

Some ceramic coatings feature additional properties, like preventing moisture migration. Some structures see up to 25 percent of HVAC costs coming from dehumidification needs, but a ceramic coating can also bring savings through moisture management. Additional features can include mold and mildew control, sound attenuation properties, and fire resistance. Spray Coating
This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers. Spray Coating
When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof.
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Coating Services
Ever wonder why it's so hot and wet inside a metal building that has spray foam insulation, in the summer and so cold and wet in winter? The metal skin magnifies the heat of the summer and frigid temperatures of the winter. Metal is a very good conductor of heat and cold. In hot weather, metal framing and sheeting rapidly radiate the sun's heat into a building. In cold weather it rapidly releases the heat out of your building. When warm air comes in contact with the cool metal sheet, condensation occurs. 
New fire safety tests for intumescent coatings were created by code officials and the spray foam industry, and many manufacturers found their closed cell spray foams could pass the test without any intumescent coating. Some open cell spray foam can pass the fire tests without an intumescent coating, but most still require the coating. Approved closed cell spray foams do not need the ignition barriers discussed above, which can make the job easier for builders. Insulation Spray Coating
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause: Spray Coating Services
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Insulation Spray Coating
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level.
E/M Coating Services has over 40 years of experience in applying critical tolerance coatings, and is a pioneer in the development and application of solid film lubricant (SFL) coatings. With its network of five U.S. facilities, E/M Coating Services is the largest applicator of solid film lubricant coatings in North America. Additional facilities in Evesham, U.K.; Unna, Germany and Tianjin & Suzhou, China apply a broad range of SFL and other coatings to steel, titanium and aluminum substrates.
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.
There have been a few mentions of intumescent coatingsabove, and it would be helpful to elaborate on them. Intumescent coating is a type of paint that will bubble when it is exposed to heat or flames. The bubbles act as a barrier that is relatively flame resistant. The bubbled coating delays the ignition of the spray foaminsulation. Because of this, intumescent coatings have become more common in building and construction.
You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Coating Services

To say spray foam insulation has become popular in green building over the past decade is like saying Peyton Manning is a good quarterback. It's an understatement. Although it's certainly not used in every green building project, it's become one of the most popular ways to build an air-tight house. In the early days, building codes hadn't caught up with how best to use this material, but that's changing. Change begets confusion, though, and the requirements for thermal and ignition barriers are one area where there's a lot of that.


Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Insulation Spray Coating
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
Open cell spray foams are less common and have a lower resistance to heat flow than closed cell spray does. Open cell spray foaminsulation expands when it is applied, which allows it to be installed in hard to reach areas, such as small wall and ceiling cavities. Open-cell spray foam is typically cheaper than closed cell foam is, but it is more permeable and vulnerable to fire hazards.
Car was washed with Carpro reset and wiped down with Griots garage paint prep to ensure a clean surface for first application of CMX. Week one CMX had a nice gloss with small tight beads after getting rained on (typical Si02 protection). Week two the beads were large and flat (low contact angle) so product was on it's way out. Week three the water was sheeting with no beading at all. That's complete failure in three weeks. Also I didn't like the white crystals that developed in the bottle. I'm concerned that if I used the product again that I'd mar my Audi's Mythos black paint. My car is parked outside driven only about 50 miles per week and is washed weekly with Megs gold class car wash. . Won't apply it again. Moving on.... Coating Services
Proper storage: Since, paints and thinners are fire hazards, extra care must be taken not only while they are in use. Fire safety should also be considered when storing paint supplies.[10] In the United States, the Occupational Safety and Health Administration (OSHA) provides guidelines for the proper storage of flammable materials.[11] Many products used in spray painting are flammable such that fire risk is likely within a distance of 15 cm from the nozzle. As such, ignition sources must be placed at a safe distance. In addition, there is a risk of dust explosions when finely-divided paint particles become airborne. Insulation Spray Coating
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Spray Coating

You like to make the tough call and enjoy having the authority to make decisions in the best interests of your customers. At PPG Coatings Services, we value those traits because our industry is constantly changing. In our business, you can't always wait for a decision, a change or a result. We constantly invest in our business, but we also invest in you, providing the skills, technical knowledge and independence you need to create loyal, satisfied and successful customers.
The criterion for whether your crawl space or attic is occupied is often the size of the entrance. Entry to the crawl space or attic should be a small hatch or door, not a normal-sized door. Additionally, if you cannot get to whatever area you are insulating without cutting through a drywall layer, then you do not need to use an ignition barrier, because the drywall already serves the purpose of the thermal barrier. Spray Coating
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating
I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating Services

This is where things get a little tricky. If a home has spray foam insulation in an attic or crawl space, the building code requires using materials or assemblies that offer some fire resistance but not as much as is required for a thermal barrier. If you've got spray foam insulation in an attic, for example, it's probably already separated from the living space by a thermal barrier. Most ceilings are made of 1/2" drywall. But the spray foam is still exposed to the attic and needs an ignition barrier.

There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary. Insulation Spray Coating


The atomization of molten materials produces a large amount of dust and fumes made up of very fine particles (ca. 80–95% of the particles by number <100 nm).[8] Proper extraction facilities are vital, not only for personal safety, but to minimize entrapment of re-frozen particles in the sprayed coatings. The use of respirators, fitted with suitable filters, is strongly recommended, where equipment cannot be isolated.[8] Certain materials offer specific known hazards:[6]
There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit.
Combustion spraying equipment produces an intense flame, which may have a peak temperature more than 3,100 °C, and is very bright. Electric arc spraying produces ultra-violet light, which may damage delicate body tissues.Plasma also generates quite a lot of UV radiation, easily burning exposed skin and can also cause "flash burn" to the eyes. Spray booths, and enclosures, should be fitted with ultra-violet absorbent dark glass. Where this is not possible, operators, and others in the vicinity should wear protective goggles containing BS grade 6 green glass. Opaque screens should be placed around spraying areas. The nozzle of an arc pistol should never be viewed directly, unless it is certain that no power is available to the equipment.[6]

Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
×