Formerly known as MetoKote, The Crown Group and Electra Finish (EFI), PPG’s coatings services applies coatings to customers’ manufactured parts and assembled products. It operates on-site coatings services within several customer manufacturing locations, as well as at regional service centers, located throughout the U.S., Canada, Mexico, the United Kingdom, Germany, Hungary and the Czech Republic. Customers ship parts to PPG service centers, where they are treated to enhance paint adhesion and painted with electrocoat, powder or liquid coatings technologies. Coated parts are then shipped to the customer’s next stage of assembly. PPG coats an average of more than 1.5 million parts per day.
Warm spraying is a novel modification of high velocity oxy-fuel spraying, in which the temperature of combustion gas is lowered by mixing nitrogen with the combustion gas, thus bringing the process closer to the cold spraying. The resulting gas contains much water vapor, unreacted hydrocarbons and oxygen, and thus is dirtier than the cold spraying. However, the coating efficiency is higher. On the other hand, lower temperatures of warm spraying reduce melting and chemical reactions of the feed powder, as compared to HVOF. These advantages are especially important for such coating materials as Ti, plastics, and metallic glasses, which rapidly oxidize or deteriorate at high temperatures.[1] Spray Coating
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
One of the most common applications we handle is the production of custom pressure sensitive adhesive tapes. We also process specialty coatings with job-specific characteristics, such as anti-fog coatings, laminating tapes, fabric appliques, and more. Custom coating formulations are also available to meet the unique requirements of virtually any application.

Most electric powered airless pumps have an electric motor connected through a gear train to the paint piston pump. Pressure is achieved by stopping and starting the motor via a pressure sensor (also called a transducer); in more advanced units, this is done by digital control in which the speed of the motor varies with the demand and the difference from the pressure set-point, resulting in a very good pressure control. Some direct drive piston pumps are driven by a gasoline engine with pressure control via an electric clutch. In electric diaphragm pumps, the motor drives a hydraulic piston pump that transmits the oil displaced by the piston, to move the diaphragm. Insulation Spray Coating
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Open cell spray foams are less common and have a lower resistance to heat flow than closed cell spray does. Open cell spray foaminsulation expands when it is applied, which allows it to be installed in hard to reach areas, such as small wall and ceiling cavities. Open-cell spray foam is typically cheaper than closed cell foam is, but it is more permeable and vulnerable to fire hazards. Coating Services

Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating
At Praxair Surface Technologies, it’s our goal to help you get more protection, more customization and more performance from your parts. To do that, we work with you to select or develop coatings based on your operating environment and production requirements. Then we combine advanced preparation services, the right application technology and post-coating operations to create optimal coating performance for any component. Coating Services
By heating the full-bodied paint to 60-80 °C, it is possible to apply a thicker coat. Originally the paint was recirculated, but as this caused bodying up, the system was changed to direct heating on line. Hot spraying was also used with Airless and Electrostatic Airless to decrease bounce-back. Two pack materials usually had premix before tip systems using dual pumps. Insulation Spray Coating
4 years ago I applied Gaco Roof, coats to an Office Building flat roof and have zero leaks since that time. This saved me $30,000 compared to having a new roof installed. The roof itself was only 7 years old when I applied Gaco Roof. but due to ponding water and harsh Florida heat and UV, the roof already looked shot and was leaking. I have now used Gaco Roof on 4 flat roofs to great results. I also tried big hardware store lower cost substitutes on 2 flat roofs. Those product utterly failed 1 to 2 years. Yes, I pressure washed my roofs clean before using Gaco Roof and followed their simple installation instructions. Excellent product. Spray Coating Services
With the increase in spray foaminsulation, many are wondering whether or not you should use a thermal or ignition barrier. Additionally, many are wondering if building codes require ignition or thermal barriers with spray foam insulation. The short answer is that you should use a thermal or ignition barrier, but the code may not necessarily require it. Building codes are often complicated, poorly written, poorly enforced, and up to interpretation by local code officials. This results in ambiguous requirements regarding spray foam insulation and fire protection.
Proper storage: Since, paints and thinners are fire hazards, extra care must be taken not only while they are in use. Fire safety should also be considered when storing paint supplies.[10] In the United States, the Occupational Safety and Health Administration (OSHA) provides guidelines for the proper storage of flammable materials.[11] Many products used in spray painting are flammable such that fire risk is likely within a distance of 15 cm from the nozzle. As such, ignition sources must be placed at a safe distance. In addition, there is a risk of dust explosions when finely-divided paint particles become airborne.

Spray painting poses health hazards that affect the respiratory, nervous, and circulatory systems. Similarly, using solvents to clean one's hands of paint marks and residue may cause skin irritation or even more serious issues since many are carcinogenic or neurotoxic. There are risks involved in working with substances such as paint and thinner, which contain compounds that are potentially harmful to health, or even fatal.[9] Insulation Spray Coating
Combustion spraying guns use oxygen and fuel gases. The fuel gases are potentially explosive. In particular, acetylene may only be used under approved conditions. Oxygen, while not explosive, will sustain combustion, and many materials will spontaneously ignite, if excessive oxygen levels are present. Care must be taken to avoid leakage, and to isolate oxygen and fuel gas supplies, when not in use.[6] Spray Coating
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Coating Services
Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.

As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor. Spray Coating Services

Vacuum plasma spraying (VPS) is a technology for etching and surface modification to create porous layers with high reproducibility and for cleaning and surface engineering of plastics, rubbers and natural fibers as well as for replacing CFCs for cleaning metal components. This surface engineering can improve properties such as frictional behavior, heat resistance, surface electrical conductivity, lubricity, cohesive strength of films, or dielectric constant, or it can make materials hydrophilic or hydrophobic.


During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Insulation Spray Coating

Enjoy year round use of your garage with Enjoy year round use of your garage with the MATADOR Garage Door Insulation Kit. Easily transform your garage space into a workshop rec room or exercise area - in less than 1 hour. The same OEM - grade product used by garage door manufacturers. Panels are a bright white with ...  More + Product Details Close Spray Coating

×