A spray booth is a pressure-controlled closed environment, originally used to paint vehicles in a body shop. To ensure the ideal working conditions (temperature, air flow, and humidity), these environments are equipped with ventilation, consisting of mechanical fans driven by electric motors, and optionally burners to heat the air to speed paint drying. Toxic solvents and paint particles are exhausted outside, possibly after filtering and treatment to reduce air pollution. Prevention of fires and dust explosions is also a high priority. In order to assist in the removal of the over sprayed paint from the air and to provide efficient operation of the down-draft, water-washed paint spray booths utilize paint detackifying chemical agents.

The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) Spray Coating
Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building. Coating Services
GacoRoof 100% Silicone Roof Coating creates a seamless membrane to seal and repair existing roofs and permanently protect against leaks, permanent ponding water and the damaging effects of severe weather. GacoRoof is available in several colors to enhance the aesthetics of any roof. Ideal for use on flat and sloped roofs including, but not limited to, large and small buildings, homes, garages and patio covers, sheds and barns, mobile homes, RVs and more.
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Spray Coating Services
E/M Coating Services has over 40 years of experience in applying critical tolerance coatings, and is a pioneer in the development and application of solid film lubricant (SFL) coatings. With its network of five U.S. facilities, E/M Coating Services is the largest applicator of solid film lubricant coatings in North America. Additional facilities in Evesham, U.K.; Unna, Germany and Tianjin & Suzhou, China apply a broad range of SFL and other coatings to steel, titanium and aluminum substrates.
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Coating Services
This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly. Spray Coating Services

This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area. Spray Coating
While intumescent coating can be used instead of an ignition barrier or thermal barrier in some cases, the coating itself is not technically either. It does prevent or slow fires, so it has been approved to be used in conjunction with spray foaminsulation as an alternate assembly. The fact that it qualifies as an alternate assembly means that it can be used instead of a thermal barrier or ignition barrier. Spray Coating Services
Mascoat is a great alternative to conventional insulation materials, including cellular glass, perlite, mineral wool, fiberglass, urethane & closed cell foam and calcium silicate. Mascoat coatings are lighter than traditional insulation, reducing bulk in your structure. Mascoat also requires much less maintenance than conventional insulation, which can ultimately save you time and money. Want to get started with Mascoat? Request more information today. Insulation Spray Coating

Spray painting is a painting technique where a device sprays a coating (paint, ink, varnish, etc.) through the air onto a surface. The most common types employ compressed gas—usually air—to atomize and direct the paint particles. Spray guns evolved from airbrushes, and the two are usually distinguished by their size and the size of the spray pattern they produce. Airbrushes are hand-held and used instead of a brush for detailed work such as photo retouching, painting nails or fine art. Air gun spraying uses equipment that is generally larger. It is typically used for covering large surfaces with an even coating of liquid. Spray guns can be either automated or hand-held and have interchangeable heads to allow for different spray patterns. Single color aerosol paint cans are portable and easy to store.
This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly. Spray Coating Services
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Spray Coating Services
I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store. Coating Services
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier.

You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Coating Services
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) Insulation Spray Coating
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Spray Coating
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Insulation Spray Coating
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Insulation Spray Coating
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
×