What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Insulation Spray Coating
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.   Spray Coating Services
Airless pumps can be powered by different types of motor: electric, compressed air (pneumatic) or hydraulic. Most have a paint pump (also called a lower) that is a double acting piston, in which the piston pumps the paint in both the down and the upstroke. Some airless pumps have a diaphragm instead of a piston, but both types have inlet and outlet valves.
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close

New fire safety tests for intumescent coatings were created by code officials and the spray foam industry, and many manufacturers found their closed cell spray foams could pass the test without any intumescent coating. Some open cell spray foam can pass the fire tests without an intumescent coating, but most still require the coating. Approved closed cell spray foams do not need the ignition barriers discussed above, which can make the job easier for builders. Insulation Spray Coating
If you are looking for the best roof coating, you should try the Heng’s. This product is protective, and can seal vents, air conditioners and more. And it’s budget friendly, we believe you will like it.This roof coating is perfect for RV rubber roof, because it can expand and contract with the roof. It can offer the best protection for the roof in any weather condition. Spray Coating Services
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating Services
In order to fulfill the requirements for an ignition barrier, most builders will choose to install a prescriptive ignition barrier such as mineral fiber insulation, install cellulose insulation, or install an approved alternate assembly of spray foam insulation coated with an intumescent coating. Recently, builders have begun using spray foam insulation that passes fire safety tests on their own, without any protective barriers or intumescent coatings.

Heat Shield™ EPX-H2O is a complete thermal barrier insulation system for pipes, tanks, and other industrial equipment and can provide 100% insulation coverage of all odd-shaped configurations – no more expensive insulation jackets or insulated covers needed. This next generation heat insulating coating has you covered for all types of directives – energy savings, safe touch for employee safety, heat radiation reduction, and asset protection from chemicals and corrosion. Don’t leave uninsulated areas in your pipe and tank insulation system that will lead to heat and energy loss. Instead use an easy spray-on solution that can coat, protect, and insulate your entire heat process system, including valves, pipes, tanks, boilers, heat exchangers, and more. Synavax™ thermal insulating and protective coating is a technology you can trust to perform consistently for 10 years or more. Spray Coating
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber. Spray Coating
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Spray Coating Services
To see if ShippingPass is right for you, try a 30-day free trial. Also, with ShippingPass, there is no need to worry about commitment. If you decide you want to discontinue the service, you can cancel your subscription at any time. No matter what your shipping needs, Walmart's got you covered. Sign up for ShippingPass so you can shop more, save money and live better. Coating Services

The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) Insulation Spray Coating
Proper storage: Since, paints and thinners are fire hazards, extra care must be taken not only while they are in use. Fire safety should also be considered when storing paint supplies.[10] In the United States, the Occupational Safety and Health Administration (OSHA) provides guidelines for the proper storage of flammable materials.[11] Many products used in spray painting are flammable such that fire risk is likely within a distance of 15 cm from the nozzle. As such, ignition sources must be placed at a safe distance. In addition, there is a risk of dust explosions when finely-divided paint particles become airborne. Spray Coating
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think.
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report
In cold spraying, particles are accelerated to very high speeds by the carrier gas forced through a converging–diverging de Laval type nozzle. Upon impact, solid particles with sufficient kinetic energy deform plastically and bond mechanically to the substrate to form a coating. The critical velocity needed to form bonding depends on the material's properties, powder size and temperature. Metals, polymers, ceramics, composite materials and nanocrystalline powders can be deposited using cold spraying.[4] Soft metals such as Cu and Al are best suited for cold spraying, but coating of other materials (W, Ta, Ti, MCrAlY, WC–Co, etc.) by cold spraying has been reported.[1] Insulation Spray Coating
Charles: That photo is closed-cell SPF, and it's not sprayed perfectly uniformly. As long as it has the minimum thickness required (3" on a ceiling here in the Atlanta area), it should be fine. I've discussed some problems with SPF installations in the articles listed in the Related Articles section above. This photo is from about 10 years ago, though, and has no ignition barrier.   Insulation Spray Coating
HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1]
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. Spray Coating Services
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier. Spray Coating
×