When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof.
In cold spraying, particles are accelerated to very high speeds by the carrier gas forced through a converging–diverging de Laval type nozzle. Upon impact, solid particles with sufficient kinetic energy deform plastically and bond mechanically to the substrate to form a coating. The critical velocity needed to form bonding depends on the material's properties, powder size and temperature. Metals, polymers, ceramics, composite materials and nanocrystalline powders can be deposited using cold spraying.[4] Soft metals such as Cu and Al are best suited for cold spraying, but coating of other materials (W, Ta, Ti, MCrAlY, WC–Co, etc.) by cold spraying has been reported.[1] Insulation Spray Coating
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies. Spray Coating
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof. Coating Services

Prodex reflects 97% of the radiant energy (primary source of heat flow) that strikes it - Which also protects your animals from Black Globe Effect. Prodex also reflects back the heat inside your steel building. Each unit of radiant heat energy that is reflected away from your barn in the summer, and each unit that is reflected back during the winter, means less operation of your heating and air conditioning system - Less wear and tear on your equipment - Less money you pay in utility costs.

I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store. Coating Services


To say spray foam insulation has become popular in green building over the past decade is like saying Peyton Manning is a good quarterback. It's an understatement. Although it's certainly not used in every green building project, it's become one of the most popular ways to build an air-tight house. In the early days, building codes hadn't caught up with how best to use this material, but that's changing. Change begets confusion, though, and the requirements for thermal and ignition barriers are one area where there's a lot of that.
While intumescent coating can be used instead of an ignition barrier or thermal barrier in some cases, the coating itself is not technically either. It does prevent or slow fires, so it has been approved to be used in conjunction with spray foaminsulation as an alternate assembly. The fact that it qualifies as an alternate assembly means that it can be used instead of a thermal barrier or ignition barrier. Spray Coating Services
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard. Coating Services
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.   Spray Coating

I ordered a 5 gallon pail of WHITE  silicone roofing to use on my 3 season porch roof. I pressure washed and scrubbed the existing roof clean. When the product came it was not white as shown on the invoice, it was tan. After all of the time I spent cleaning and being that i travel for work, i did not have time to send it back and get the WHITE I had ordered. I applied two full coats of the tan and it went on well and looks good. Other that the color I am satisfied so far. I will likely not purchase from  Roof Coating Supply company again as they did not even respond to my complaint about the color.
Car was washed with Carpro reset and wiped down with Griots garage paint prep to ensure a clean surface for first application of CMX. Week one CMX had a nice gloss with small tight beads after getting rained on (typical Si02 protection). Week two the beads were large and flat (low contact angle) so product was on it's way out. Week three the water was sheeting with no beading at all. That's complete failure in three weeks. Also I didn't like the white crystals that developed in the bottle. I'm concerned that if I used the product again that I'd mar my Audi's Mythos black paint. My car is parked outside driven only about 50 miles per week and is washed weekly with Megs gold class car wash. . Won't apply it again. Moving on.... Coating Services
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend?

This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers. Coating Services


Our elastomeric rubber coatings for metal roofs provide unmatched flexibility and resistance against harsh weather conditions. From tin roof sealant to corrugated and rusty metal roof sealants, our products are specially formulated for a wide variety of metal roof types. Check out our full selection of rubber coatings for metal roofs below, in addition to application instructions for the best results.
Our insulation and protective coatings are designed for the harshest outdoor and offshore environments, such as those experienced by our customer Sinopec on their offshore fuel oil storage tanks, black liquor tanks in pulp and paper mills like those of Weyerhaeuser, and even in the frigid cold of Alaska where our thermal barrier insulation coatings helped insulate steam and water pipes for the U.S. Army. Our customers choose Synavax™ industrial and building insulating coating solutions because of the superior combined energy savings, stay clean, and asset protection benefits. Spray Coating Services
I've used P&S BeadMaker, Meguiars Express Wax, Carnuba Wax, CMX and most recently Meguiars Hybrid Wax. To tell you the truth, if you're a gloss and slick addict, it really boils down to how well you prep your car. Wash, clay bar, compund, and polish. IPA wipe down. Anything else you put on after will highlight the shine you prepped with all the pre-work.
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below).
I have learned to like this product by using a different method of application. Rather than spraying the sealant directly on the paint surface, I've learned that applying it to a MF applicator pad then spreading evenly and buffing off works best to avoid the crystal dusting. The durability is very impressive for a spray sealant. After 1 month, the water beading is still 100% active and the added gloss is still present.
Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below). Spray Coating Services
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. Spray Coating Services
Condensation - It can seem like a tropical rain forest inside an unprotected metal building. It's worse on those days where there is a greater contrast between temperatures at night vs. day. The morning sun hitting the cool sheeting will create a drip. A temperature difference between outside and inside your building creates condensation - Similar to what happens when you leave a cold can of beer outside on a hot day.  Insulation Spray Coating
Electrostatic painting was first patented in the U.S. by Harold Ransburg in the late 1940s. Harold Ransburg founded Ransburg Electrostatic Equipment and discovered that electrostatic spray painting was an immediate success as manufacturers quickly perceived the substantial materials savings that could be achieved. In electrostatic spray painting or powder coating, the atomized particles are made to be electrically charged, thereby repelling each other and spreading themselves evenly as they exit the spray nozzle. The object being painted is charged oppositely or grounded. The paint is then attracted to the object giving a more even coat than wet spray painting, and also greatly increasing the percentage of paint that sticks to the object. This method also means that paint covers hard to reach areas. The whole may then be baked to properly attach the paint: the powder turns into a type of plastic. Car body panels and bike frames are two examples where electrostatic spray painting is often used.
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria.
I finally completed my 60" X 42" steel building using your insulation between the steel studs and the metal sheeting. I was amazed at the temperature difference. The metal is not allowed to adversely heat the building and the temperature is cooler than under a shade tree because of the breeze created within the door openings. The reflective foil also provides a tremendous amount of light reflection inside the building creating a very bright look inside. I am amazed and presently surprised that the thin foil actually worked so well.
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report
Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable. Coating Services
With all good DIY projects, you need to start with quality products to get the job done right. Krylon spray paints can cover anything from plastic and metal to cement and more. Use Krylon blue spray paint, Krylon green spray paint or Krylon yellow spray paint in a stained-glass finish to make a new table centerpiece. Krylon red spray paint, Krylon purple spray paint and Krylon orange spray paint can revitalize old patio décor into a vibrant outdoor space. Breathe new life into patio planters with Krylon brown spray paint. It’s easy to stay on trend with Krylon pink spray paint or get creative with Krylon metallic spray paint. With all these colors, the possibilities are endless. For projects that need just the basics, Krylon white spray paint, Krylon black spray paint and Krylon gray spray paint can help you tackle any job.
Spray polyurethan foam does effectly prevent all six of these heat transfer methods from occurring. These should be the mechanisms by which you judge insulation, in addition to their R-Value. If you're uncertain about installing spray foam insulation, Energy Star has a map that recommends levels of insulation by R-value and cost-effectiveness in the United States.
I've used P&S BeadMaker, Meguiars Express Wax, Carnuba Wax, CMX and most recently Meguiars Hybrid Wax. To tell you the truth, if you're a gloss and slick addict, it really boils down to how well you prep your car. Wash, clay bar, compund, and polish. IPA wipe down. Anything else you put on after will highlight the shine you prepped with all the pre-work.
“The true key to insulation is preventing heat load,” says J.E. Pritchett, founder and developer of SuperTherm, a ceramic coating product produced by Superior Products International. The concept is simple: Why use fiberglass insulation to slow the transfer of heat into a building when you can just prevent that heat from ever loading onto the building in the first place? If heat is kept off the structure to begin with, that fiberglass insulation becomes unnecessary. It’s a change in the way we think about insulating our homes against energy lost. “R rating is for the 20th century,” says Pritchett. “Emissivity is 21st century.”

Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable. Coating Services
Electrostatic painting was first patented in the U.S. by Harold Ransburg in the late 1940s. Harold Ransburg founded Ransburg Electrostatic Equipment and discovered that electrostatic spray painting was an immediate success as manufacturers quickly perceived the substantial materials savings that could be achieved. In electrostatic spray painting or powder coating, the atomized particles are made to be electrically charged, thereby repelling each other and spreading themselves evenly as they exit the spray nozzle. The object being painted is charged oppositely or grounded. The paint is then attracted to the object giving a more even coat than wet spray painting, and also greatly increasing the percentage of paint that sticks to the object. This method also means that paint covers hard to reach areas. The whole may then be baked to properly attach the paint: the powder turns into a type of plastic. Car body panels and bike frames are two examples where electrostatic spray painting is often used. Coating Services
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through:
A rule of thumb puts two thirds of the coating on the substrate and one third in the air. True HVLP guns use 8–20 cfm (13.6–34 m3/h), and an industrial compressor with a minimum of 5 horsepower (3.7 kW) output is required. HVLP spray systems are used in the automotive, decorative, marine, architectural coating, furniture finishing, scenic painting, and cosmetic industries. Spray Coating
×