Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else.  Spray Coating
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think. Spray Coating
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Spray Coating
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.

Legend Coatings and Insulation values the integrity of our work. We have extensive training when it comes to spray application. All of our applicators at Legend are trained and certified to industry standards. We do not stand alone when it comes to the building science behind our systems . We work hand in hand with Certified HVAC Contractors, Architects and Building Officials to combine our experience and expertise to find the best possible system to suite your needs and maximize your investment. Spray Coating
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc. Insulation Spray Coating
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1]
Spray painting is a painting technique where a device sprays a coating (paint, ink, varnish, etc.) through the air onto a surface. The most common types employ compressed gas—usually air—to atomize and direct the paint particles. Spray guns evolved from airbrushes, and the two are usually distinguished by their size and the size of the spray pattern they produce. Airbrushes are hand-held and used instead of a brush for detailed work such as photo retouching, painting nails or fine art. Air gun spraying uses equipment that is generally larger. It is typically used for covering large surfaces with an even coating of liquid. Spray guns can be either automated or hand-held and have interchangeable heads to allow for different spray patterns. Single color aerosol paint cans are portable and easy to store. Coating Services
Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct? Spray Coating Services

Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below). Coating Services

The criterion for whether your crawl space or attic is occupied is often the size of the entrance. Entry to the crawl space or attic should be a small hatch or door, not a normal-sized door. Additionally, if you cannot get to whatever area you are insulating without cutting through a drywall layer, then you do not need to use an ignition barrier, because the drywall already serves the purpose of the thermal barrier. Spray Coating


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.

What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Spray Coating

Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building.
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Coating Services
The standard prescriptive material that can be used as a thermal barrier is 1/2" gypsum board (a.k.a. drywall or sheetrock). Anything else has to be approved as an 'equivalent thermal barrier' by undergoing tests for temperature transmission and fire integrity. In some cases, however, you need only one test. According to the Spray Polyurethane Foam Alliance (SPFA), "Under specific conditions, the temperature transmission test can be waived if approved by building code authorities on the basis of large-scale fire testing representing actual uses." (See their pdf document, Thermal and Ignition Barriers For The SPF Industry.) Spray Coating Services
Prodex reflects 97% of the radiant energy (primary source of heat flow) that strikes it - Which also protects your animals from Black Globe Effect. Prodex also reflects back the heat inside your steel building. Each unit of radiant heat energy that is reflected away from your barn in the summer, and each unit that is reflected back during the winter, means less operation of your heating and air conditioning system - Less wear and tear on your equipment - Less money you pay in utility costs. Spray Coating
I've had concerns with foam in walls with only 2-3" and the resulting air space & convective currents. spray foam for walls is not one of my recommendations to my clients. instead foam sheathing to exterior of walls caulked,taped & sealed. conventional insulation & air tight drywall approach. a better and affordable wall with no extremely long payback like spray foam in walls.  Insulation Spray Coating
When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof. Spray Coating
×