Inspired in part by the ceramic tiles that NASA uses on the Space Shuttle, a ceramic coating is a paint mixed with one or more ceramic compounds for application via spray or roller to exterior and interior surfaces. Depending on the ceramic compounds used (there are hundreds of varieties), this insulating product has the ability to prevent heat transfer and heat loading onto a structure. This means heat will not transfer into or out of a building. Coating Services


Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings.
I installed Prodex in my 40'x40'x14' Steel garage when I bought the building it came with the 4" thick 6' wide white vinyl that was hard to work with because of it's weight and bulkiness. The weather was rainy and it was just my wife and I installing the insulation and steel sheeting. Trying to find something easier to work with I found your product I ordered enough to line the entire garage it was grate to work with. When the garage door company cam to install the garage doors on January 02/2010 the temperature outside was 10 degrees and windy. After they had the door tracks fastened enough to hold the doors in place they light there portable gas salamander I was impressed with how quickly it warmed to 40 degrees and healed the heat after they turned it off.
Mass-produced material is loaded on a conveyor belt where it is fed into one of these flatline machines. Flatline machines are designed to specifically paint material that is less than 4 inches (10 cm) thick and complex in shape, for example a kitchen cabinet door or drawer front. Spray guns are aligned above the material and the guns are in motion in order to hit all the grooves of the material. The guns can be moved in a cycle, circle, or can be moved back and forth in order to apply paint evenly across the material. Flatline systems are typically large and can paint doors, kitchen cabinets, and other plastic or wooden products. Insulation Spray Coating
Building code uses two different terms to describe barriers that protect insulation and prevent them from catching fire. The first is called a thermal barrier, which is a poorly chosen word. Typically, scientists and builders refer to insulation as a thermal barrier. Most people would think of a thermal barrier as something that keeps heat in. However, in building code, thermal barrier essentially refers to 1/2-inch drywall, though the definition can get more complicated than that.
Heat Shield™ EPX-H2O is a complete thermal barrier insulation system for pipes, tanks, and other industrial equipment and can provide 100% insulation coverage of all odd-shaped configurations – no more expensive insulation jackets or insulated covers needed. This next generation heat insulating coating has you covered for all types of directives – energy savings, safe touch for employee safety, heat radiation reduction, and asset protection from chemicals and corrosion. Don’t leave uninsulated areas in your pipe and tank insulation system that will lead to heat and energy loss. Instead use an easy spray-on solution that can coat, protect, and insulate your entire heat process system, including valves, pipes, tanks, boilers, heat exchangers, and more. Synavax™ thermal insulating and protective coating is a technology you can trust to perform consistently for 10 years or more. Spray Coating
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary.
Some ceramic coatings feature additional properties, like preventing moisture migration. Some structures see up to 25 percent of HVAC costs coming from dehumidification needs, but a ceramic coating can also bring savings through moisture management. Additional features can include mold and mildew control, sound attenuation properties, and fire resistance. Spray Coating
Due to a wide range of nozzle shapes and sizes, the consistency of the paint can be varied. The shape of the workpiece and the desired paint consistency and pattern are important factors when choosing a nozzle. The three most common nozzles are the full cone, hollow cone, and flat stream.[6] There are two types of air-gun spraying processes. In a manual operation method the air-gun sprayer is held by a skilled operator, about 6 to 10 inches (15–25 cm) from the object, and moved back and forth over the surface, each stroke overlapping the previous to ensure a continuous coat.[7] In an automatic process the gun head is attached to a mounting block and delivers the stream of paint from that position. The object being painted is usually placed on rollers or a turntable to ensure overall equal coverage of all sides. Coating Services
Synavax™ thermal insulation coatings help organizations improve energy efficiency. They are nano-engineered patented cutting-edge thermal paint coatings that provide next generation performance beyond older, non-patented ceramic insulation products.  Additionally, our products are eco-friendly and provide mold-resistant and anti-condensation properties without harmful biocides and other harsh chemicals, which is a significant plus for sustainably-minded companies.
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.   Spray Coating
Hydraulic or air powered airless provide a more uniform pressure control since the paint piston moves at a constant speed except when it changes direction. In most direct drive piston pumps, the piston is crankshaft driven in which the piston will be constantly changing speed. The linear motors of hydraulic or compressed air drive pumps, are more efficient in converting engine power to material power, than crankshaft driven units. All types of paint can be painted by using airless method.
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Spray Coating
×