Chris M.: Yes, I meant to mention in the article that this applies to both open cell (a.k.a. low density or 1/2 pound SPF) and closed cell (a.k.a. medium density or 2 pound SPF). Foam board insulation also needs to meet the requirements for thermal and ignition barriers, and some products, like Dow Thermax, have gotten approval to be left exposed. 

Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.


Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Insulation Spray Coating
Heat Shield™ EPX-H2O is a complete thermal barrier insulation system for pipes, tanks, and other industrial equipment and can provide 100% insulation coverage of all odd-shaped configurations – no more expensive insulation jackets or insulated covers needed. This next generation heat insulating coating has you covered for all types of directives – energy savings, safe touch for employee safety, heat radiation reduction, and asset protection from chemicals and corrosion. Don’t leave uninsulated areas in your pipe and tank insulation system that will lead to heat and energy loss. Instead use an easy spray-on solution that can coat, protect, and insulate your entire heat process system, including valves, pipes, tanks, boilers, heat exchangers, and more. Synavax™ thermal insulating and protective coating is a technology you can trust to perform consistently for 10 years or more.
Charles spoke of a "huge problem" of convection within cavities not filled with foam. This is a false assertion. The trillions of trapped air cells in foam insulation prevent heat transfer at a rate that would cause those problems. Also the wood framing members are relatively good insulators themselves unless the wood is particularly dense. Convection currents against foam insulation are not the problem he asserts. He also said" the homeowner is literally pissing money away if he pays for this spray foam job - or any job like it - for he will only be gaining a marginal amount of insulation effectiveness." This is a ludicrous statement. The structure pictured above will have a very effective performance despite his assertions. My only concern is humidity. Closed cell foam does not permit moisture migration and trapped moisture could be a problem, especially if the AC is not running due to moderate to cold temperatures.
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Insulation Spray Coating
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can.
“Since most of mechanical heat is IR heat, ceramic coatings can be used to prevent heat loss from inside a building,” Pritchett says. A home interior coated in ceramic paint can therefore reduce energy costs due to heat loss in the colder months. “We estimate that a home can save up to 40 to 50 percent in energy costs using our product,” Pritchett says. Payback on a product like SuperTherm, which retails for about $100 per gallon, can come in as little as two years.

The detonation gun consists of a long water-cooled barrel with inlet valves for gases and powder. Oxygen and fuel (acetylene most common) are fed into the barrel along with a charge of powder. A spark is used to ignite the gas mixture, and the resulting detonation heats and accelerates the powder to supersonic velocity through the barrel. A pulse of nitrogen is used to purge the barrel after each detonation. This process is repeated many times a second. The high kinetic energy of the hot powder particles on impact with the substrate results in a buildup of a very dense and strong coating. Coating Services
Blocking heat buildup is a complicated task. Heat comes in three forms: ultra-violet (UV), visible light, and infrared (IR). A quality ceramic coating will block all three, especially IR, which is responsible for roughly 57 percent of heat load on a building. “Some ceramic paints claim to block all heat caused by UV,” says Pritchett, “but UV only accounts for three percent of heat load on a building.” Coating Services
When do you need an ignition barrier? According to the IRC and IBC, an attic or crawl space needs an ignition barrier over the spray foam if the space can be accessed but will not be used for storage or auxiliary living space. You don't need an ignition barrier if the space cannot be accessed without cutting into it, if it is not connected to other spaces, and if it does not communicate with other spaces. Spray Coating Services
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating

Most electric powered airless pumps have an electric motor connected through a gear train to the paint piston pump. Pressure is achieved by stopping and starting the motor via a pressure sensor (also called a transducer); in more advanced units, this is done by digital control in which the speed of the motor varies with the demand and the difference from the pressure set-point, resulting in a very good pressure control. Some direct drive piston pumps are driven by a gasoline engine with pressure control via an electric clutch. In electric diaphragm pumps, the motor drives a hydraulic piston pump that transmits the oil displaced by the piston, to move the diaphragm. Coating Services
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Formerly known as MetoKote, The Crown Group and Electra Finish (EFI), PPG’s coatings services applies coatings to customers’ manufactured parts and assembled products. It operates on-site coatings services within several customer manufacturing locations, as well as at regional service centers, located throughout the U.S., Canada, Mexico, the United Kingdom, Germany, Hungary and the Czech Republic. Customers ship parts to PPG service centers, where they are treated to enhance paint adhesion and painted with electrocoat, powder or liquid coatings technologies. Coated parts are then shipped to the customer’s next stage of assembly. PPG coats an average of more than 1.5 million parts per day.
High volume low pressure (HVLP) is similar to a conventional spray gun using a compressor to supply the air, but the spray gun itself requires a lower pressure (LP). A higher volume (HV) of air is used to aerosolise and propel the paint at lower air pressure. The result is a higher proportion of paint reaching the target surface with reduced overspray, materials consumption, and air pollution. A regulator is often required so that the air pressure from a conventional compressor can be lowered for the HVLP spray gun. Alternatively a turbine unit (commonly containing a vacuum cleaner derived motor) can be used to propel the air without the need for an air line running to the compressor. Coating Services
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc. Spray Coating Services

For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
You are eligible for a full refund if no ShippingPass-eligible orders have been placed. You cannot receive a refund if you have placed a ShippingPass-eligible order. In this case, the Customer Care team will remove your account from auto-renewal to ensure you are not charged for an additional year and you can continue to use the subscription until the end of your subscription term.
The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important. Spray Coating Services
In recent years, there has been a significant rise in the use of spray foam insulation in construction. Spray foam insulation varies from traditional insulation, such as fiberglass, in many respects. Fiberglass insulation is typically much cheaper than spray foam insulation; however, it is also less effective at insulating your home. Additionally, spray foaminsulation requires professional installation. Though spray foam insulation is on the rise, fiberglass is still the most common form of home insulation used today.
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock.
PPG Coatings Services has protective coatings production facilities, sales offices and a network of representatives strategically located around the world. That means you can reap the benefits of working with one of the world’s largest and most innovative coatings companies while enjoying the personalized service of a smaller organization focused on meeting the needs of your business.
These operate connected to a high pressure pump commonly found using 300 to 7,500 pounds per square inch (2,100–51,700 kPa) pressure to atomize the coating, using different tip sizes to achieve desired atomization and spray pattern size. This type of system is used by contract painters to paint heavy duty industrial, chemical and marine coatings and linings.
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Spray Coating
I applied this product on a rolled asphalt flat patio roof. It was over 90 degrees and I could not touch the roofing at all on the first coat. I was laying on layers of cardboard to apply the silicone under the gutters and then rolled the first coat. The next day I brought all the cardboard to apply the coating under the gutters. I accidentally touched the roof and it was cool‼️  I threw the cardboard off the roof, laid down to do the gutters and roll the second coat. I was amazed how well this sealed and cooled the patio. I am going to apply this to my other patio and covered parking which are metal. I can’t wait to apply for sealing and adding cooling to these areas. Roof Coating Supply answered all my question and they ship promptly - I had my order in 3 days. Thank you. Coating Services

With the increase in spray foaminsulation, many are wondering whether or not you should use a thermal or ignition barrier. Additionally, many are wondering if building codes require ignition or thermal barriers with spray foam insulation. The short answer is that you should use a thermal or ignition barrier, but the code may not necessarily require it. Building codes are often complicated, poorly written, poorly enforced, and up to interpretation by local code officials. This results in ambiguous requirements regarding spray foam insulation and fire protection.
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others.

By heating the full-bodied paint to 60-80 °C, it is possible to apply a thicker coat. Originally the paint was recirculated, but as this caused bodying up, the system was changed to direct heating on line. Hot spraying was also used with Airless and Electrostatic Airless to decrease bounce-back. Two pack materials usually had premix before tip systems using dual pumps. Spray Coating


As discussed, many closed cell (and even some open cell) foam sprays do not need additional layers to serve as an ignition barrier. It is possible to use these spray foams, and leave them exposed in attics and crawl spaces. Additionally, you can use alternate assembly spray foams with intumescent coats and leave them exposed in an attic or crawl space without the use of an ignition barrier. In order for these methods to be accepted by code officials, the spray foammust be sprayed in the same exact manner they were in the assembly test in the laboratory.
In recent years, there has been a significant rise in the use of spray foam insulation in construction. Spray foam insulation varies from traditional insulation, such as fiberglass, in many respects. Fiberglass insulation is typically much cheaper than spray foam insulation; however, it is also less effective at insulating your home. Additionally, spray foaminsulation requires professional installation. Though spray foam insulation is on the rise, fiberglass is still the most common form of home insulation used today.
These are robust production capabilities, which allow us to consistently and reliably meet a broad range of coating requirements. Our technical managers ensure the substrate and coating are compatible and are the best possible materials for the job. We engineer our process to deliver a uniform coating in a precise layer from .001” to .005” in thickness. Insulation Spray Coating

once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly. Spray Coating Services
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.) Spray Coating Services
Wire arc spray is a form of thermal spraying where two consumable metal wires are fed independently into the spray gun. These wires are then charged and an arc is generated between them. The heat from this arc melts the incoming wire, which is then entrained in an air jet from the gun. This entrained molten feedstock is then deposited onto a substrate with the help of compressed air. This process is commonly used for metallic, heavy coatings.[1] Spray Coating Services

 This stuff works perfectly! We'll see how long it holds up on my nicely prepped paint on my black 1996 Jeep Cherokee. I first hand washed it, then used Meguiars Clay Bar kit on it, then compounded it using Meguiars Ultimate Compound, then polished it using Meguiars polish, then used wax and grease remover to remove any oily residue from the previous steps, then applied the Mother's CMX using a microfiber foam hand applicator to spread one spray at a time evenly across the paint... Let it sit for a few minutes to bond with the paint surface, then used a really soft microfiber towel that came with my clay bar kit to buff off the dried powder residue to a perfect shine!! It wiped off very easily and then let it sit to cure for 24 hours without getting wet... It looks flawless on my fresh black paint! And water falls right off of it like all the other great brand ceramic coatings!! Highly recommend it especially for the price and the big bottle... This stuff has a very strong smell to it (must be good!), and is completely white like milk inside it if you unscrew the cap and have a look at it... I'm very satisfied, this was my first time ever using a ceramic coating before and it worked exactly how they claimed and advertised in their video Ads on FACEBOOK Coating Services
Synavax™ thermal insulation coatings are the top choice for a wide variety of thermal insulating paint applications over equipment like pipes, pipelines, tanks, ovens, processing vessels, heat exchangers and more. Synavax™ patented industrial thermal insulation paint solves corrosion-under-insulation (CUI) by both insulating and preventing corrosion with a single product. Our thermal paint coatings are multipurpose spray or paint applied products that are simple to deploy.
Vacuum plasma spraying (VPS) is a technology for etching and surface modification to create porous layers with high reproducibility and for cleaning and surface engineering of plastics, rubbers and natural fibers as well as for replacing CFCs for cleaning metal components. This surface engineering can improve properties such as frictional behavior, heat resistance, surface electrical conductivity, lubricity, cohesive strength of films, or dielectric constant, or it can make materials hydrophilic or hydrophobic.
I applied this product on a rolled asphalt flat patio roof. It was over 90 degrees and I could not touch the roofing at all on the first coat. I was laying on layers of cardboard to apply the silicone under the gutters and then rolled the first coat. The next day I brought all the cardboard to apply the coating under the gutters. I accidentally touched the roof and it was cool‼️  I threw the cardboard off the roof, laid down to do the gutters and roll the second coat. I was amazed how well this sealed and cooled the patio. I am going to apply this to my other patio and covered parking which are metal. I can’t wait to apply for sealing and adding cooling to these areas. Roof Coating Supply answered all my question and they ship promptly - I had my order in 3 days. Thank you. Spray Coating Services

The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
A rule of thumb puts two thirds of the coating on the substrate and one third in the air. True HVLP guns use 8–20 cfm (13.6–34 m3/h), and an industrial compressor with a minimum of 5 horsepower (3.7 kW) output is required. HVLP spray systems are used in the automotive, decorative, marine, architectural coating, furniture finishing, scenic painting, and cosmetic industries. Spray Coating
×