The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.   Spray Coating Services
During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Insulation Spray Coating
This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area. Spray Coating
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.   Spray Coating Services
Synavax™ thermal insulation coatings are the top choice for a wide variety of thermal insulating paint applications over equipment like pipes, pipelines, tanks, ovens, processing vessels, heat exchangers and more. Synavax™ patented industrial thermal insulation paint solves corrosion-under-insulation (CUI) by both insulating and preventing corrosion with a single product. Our thermal paint coatings are multipurpose spray or paint applied products that are simple to deploy.
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof? Insulation Spray Coating
This product creates a reflective silver finish, thus to help protect roof surfaces and lower roof surface temperature. It uses a low solvent formula, so it dries faster than other roof coatings.This roof coating can be applied by brush, roller or sprayer tip size .040-.061, 1000-1500 psi. We remind you that this product is not suitable for roof repairing, because it can not seal properly.
Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code. Spray Coating
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Spray Coating Services
Due to a wide range of nozzle shapes and sizes, the consistency of the paint can be varied. The shape of the workpiece and the desired paint consistency and pattern are important factors when choosing a nozzle. The three most common nozzles are the full cone, hollow cone, and flat stream.[6] There are two types of air-gun spraying processes. In a manual operation method the air-gun sprayer is held by a skilled operator, about 6 to 10 inches (15–25 cm) from the object, and moved back and forth over the surface, each stroke overlapping the previous to ensure a continuous coat.[7] In an automatic process the gun head is attached to a mounting block and delivers the stream of paint from that position. The object being painted is usually placed on rollers or a turntable to ensure overall equal coverage of all sides. Coating Services
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Spray Coating
Synavax™ thermal insulation coatings are the top choice for a wide variety of thermal insulating paint applications over equipment like pipes, pipelines, tanks, ovens, processing vessels, heat exchangers and more. Synavax™ patented industrial thermal insulation paint solves corrosion-under-insulation (CUI) by both insulating and preventing corrosion with a single product. Our thermal paint coatings are multipurpose spray or paint applied products that are simple to deploy. Spray Coating Services

I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.
Weather & Drying Guidelines: Ames® Super Primer™, Maximum-Stretch® and Iron Coat® is best applied between 50° to 90° F (10° to 32° C) on warm dry surfaces. Apply when the streets are dry, the sun is in the sky and no inclement weather is forecast. Starts to dry in about 2-8 hours, depending on thickness of application and weather. It is recommended to allow a minimum of 24 hours between coats with no rain in the forecast and no freezing temperatures. Low temperatures, high humidity and evening and morning dew will require increased drying/curing time. Do not apply after 2pm for best drying. The earlier you can put it on, the better. Make sure any morning dew is completely dried off before proceeding. Spray Coating
Wire arc spray is a form of thermal spraying where two consumable metal wires are fed independently into the spray gun. These wires are then charged and an arc is generated between them. The heat from this arc melts the incoming wire, which is then entrained in an air jet from the gun. This entrained molten feedstock is then deposited onto a substrate with the help of compressed air. This process is commonly used for metallic, heavy coatings.[1] Spray Coating Services

The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber.


FIRESHELL® (F10E) is a proprietary non-flammable, intumescing (expands up to 2000%) interior coating that provides oxygen starvation to fire. It is a non-toxic, water based, drain safe, no fuming GREEN product. FIRESHELL® passes full scale room corner over foam, NFPA 286 and E84 class A certified. Meets requirements for 15 minute thermal barrier. It is a water-based one part coating system that comes white but can be tinted different colors. This coating can be top-coated with either latex or oil based coating. Insulation Spray Coating

Proper recordkeeping: One of the basic tenets of risk control is maintenance of updated health records of personnel handling spray paint products. Confidential data on biological monitoring[12] results must be appropriately kept.[13] Records of the schedule and result of testing procedures should also be kept. Some of the most important tests to be conducted on a regular basis are air quality testing, testing of pressure systems and electrical systems, and testing of compressor reservoir air filters.


When intumescent coatings are used with spray foaminsulation, they are specific to each insulation brand. You cannot use one intumescent coating with a brand that it was not intended for. If you do not use the properspray foaminsulation brand and intumescent coating combination, then your work will not technically be up to code. Additionally, it is important to keep in mind that intumescent coating can only be used as an ignition barrier alternative if it is being used in an attic or crawl space. And, even then, it can only be used if space is not used for storage and is accessible through a small hatch or door.
Warm spraying is a novel modification of high velocity oxy-fuel spraying, in which the temperature of combustion gas is lowered by mixing nitrogen with the combustion gas, thus bringing the process closer to the cold spraying. The resulting gas contains much water vapor, unreacted hydrocarbons and oxygen, and thus is dirtier than the cold spraying. However, the coating efficiency is higher. On the other hand, lower temperatures of warm spraying reduce melting and chemical reactions of the feed powder, as compared to HVOF. These advantages are especially important for such coating materials as Ti, plastics, and metallic glasses, which rapidly oxidize or deteriorate at high temperatures.[1] Spray Coating
The standard prescriptive material that can be used as a thermal barrier is 1/2" gypsum board (a.k.a. drywall or sheetrock). Anything else has to be approved as an 'equivalent thermal barrier' by undergoing tests for temperature transmission and fire integrity. In some cases, however, you need only one test. According to the Spray Polyurethane Foam Alliance (SPFA), "Under specific conditions, the temperature transmission test can be waived if approved by building code authorities on the basis of large-scale fire testing representing actual uses." (See their pdf document, Thermal and Ignition Barriers For The SPF Industry.) Spray Coating Services

Health monitoring: In order to avoid development of illnesses associated with exposure to isocyanates, health authorities recommend that people who use spray paint products that contain the substance provide a urine sample after a work shift at least once a year, with high frequencies in first few months on the job. A urine sample with ascertain levels of exposure, not the presence of disease associated with harmful chemicals.

Since our founding in 1973, Dal-Bac Manufacturing Co., Inc. has grown and expanded to become one of the premier providers of coating services to customers in a diverse range of industries. We are capable of applying both solvent and water-borne coatings to a wide variety of substrates, including fabrics, films, foams, and papers. Our capabilities include both knife-over-roll and Meyer rod coating methods for roll goods up to 61” in width. With our custom built equipment, we process materials accurately and cost-effectively. Spray Coating


Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable. Coating Services

The CWST Thermal Spraying, FW Gartner and Bolts Metallizing business units in AZ, CT, MA, SC and TX apply HVOF, HVAF and plasma thermal spray coatings for flight and industrial gas turbine applications as well as tungsten and chrome carbide wear coatings utilized in Oil & Gas, Mining, Steel Mill and other demanding industrial markets. FW Gartner also provides Laser Cladding and PTA welding services on new and service run parts for components operating in severe service environments.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response.  Spray Coating Services
Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings. Spray Coating
High volume low pressure (HVLP) is similar to a conventional spray gun using a compressor to supply the air, but the spray gun itself requires a lower pressure (LP). A higher volume (HV) of air is used to aerosolise and propel the paint at lower air pressure. The result is a higher proportion of paint reaching the target surface with reduced overspray, materials consumption, and air pollution. A regulator is often required so that the air pressure from a conventional compressor can be lowered for the HVLP spray gun. Alternatively a turbine unit (commonly containing a vacuum cleaner derived motor) can be used to propel the air without the need for an air line running to the compressor.
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause: Spray Coating Services

 This stuff works perfectly! We'll see how long it holds up on my nicely prepped paint on my black 1996 Jeep Cherokee. I first hand washed it, then used Meguiars Clay Bar kit on it, then compounded it using Meguiars Ultimate Compound, then polished it using Meguiars polish, then used wax and grease remover to remove any oily residue from the previous steps, then applied the Mother's CMX using a microfiber foam hand applicator to spread one spray at a time evenly across the paint... Let it sit for a few minutes to bond with the paint surface, then used a really soft microfiber towel that came with my clay bar kit to buff off the dried powder residue to a perfect shine!! It wiped off very easily and then let it sit to cure for 24 hours without getting wet... It looks flawless on my fresh black paint! And water falls right off of it like all the other great brand ceramic coatings!! Highly recommend it especially for the price and the big bottle... This stuff has a very strong smell to it (must be good!), and is completely white like milk inside it if you unscrew the cap and have a look at it... I'm very satisfied, this was my first time ever using a ceramic coating before and it worked exactly how they claimed and advertised in their video Ads on FACEBOOK


E/M Coating Services has over 40 years of experience in applying critical tolerance coatings, and is a pioneer in the development and application of solid film lubricant (SFL) coatings. With its network of five U.S. facilities, E/M Coating Services is the largest applicator of solid film lubricant coatings in North America. Additional facilities in Evesham, U.K.; Unna, Germany and Tianjin & Suzhou, China apply a broad range of SFL and other coatings to steel, titanium and aluminum substrates.
The video below is from a house near Charleston, South Carolina that I visited recently, and you'll see that the homeowner in this case didn't get his money's worth. I knew immediately when I walked into the attic that something was wrong because it was hot up there. In a properly insulated spray foam attic, the temperature won't be much higher than the house temperature.  Coating Services
The deposits consist of a multitude of pancake-like 'splats' called lamellae, formed by flattening of the liquid droplets. As the feedstock powders typically have sizes from micrometers to above 100 micrometers, the lamellae have thickness in the micrometer range and lateral dimension from several to hundreds of micrometers. Between these lamellae, there are small voids, such as pores, cracks and regions of incomplete bonding. As a result of this unique structure, the deposits can have properties significantly different from bulk materials. These are generally mechanical properties, such as lower strength and modulus, higher strain tolerance, and lower thermal and electrical conductivity. Also, due to the rapid solidification, metastable phases can be present in the deposits. Insulation Spray Coating
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier. Spray Coating
×