Independent reviews at Site Jabber. Site Jabber is the leading community of online business reviewers. The community helps consumers find great online business and avoid scams. The community has grown to over 850,000 members and has reviewed over 58,000 online businesses. Site Jabber was developed in part with a grant from the National Science Foundation. Spray Coating Services

We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code. Spray Coating
RE: my June 12 post...We went ahead and had the attic sprayed with a Soy-based product. Stayed in a hotel for 3 nites. Still smelled a little bad but that's gone away over time. I'm very glad we didn't use the other foam as even that much outgassing of a petrochemical could have sent my wife to the hospital. Unfortunately, the spray crew didn't speak English(at least not to me) and were kinda lazy, so they ended up spraying over some can fixtures from the kitchen below that were not insulation-contact rated. So I hired an electrician to come out, pull down the cans, pull out what he thought was an appropriate amount of foam to create a big enough air space and then re-install the cans. I billed the firm for the electrician plus an extra night we had to stay in the hotel and they paid, no questions asked. Guess they knew they had screwed up.  

I applied this product on a rolled asphalt flat patio roof. It was over 90 degrees and I could not touch the roofing at all on the first coat. I was laying on layers of cardboard to apply the silicone under the gutters and then rolled the first coat. The next day I brought all the cardboard to apply the coating under the gutters. I accidentally touched the roof and it was cool‼️  I threw the cardboard off the roof, laid down to do the gutters and roll the second coat. I was amazed how well this sealed and cooled the patio. I am going to apply this to my other patio and covered parking which are metal. I can’t wait to apply for sealing and adding cooling to these areas. Roof Coating Supply answered all my question and they ship promptly - I had my order in 3 days. Thank you.
In recent years, there has been a significant rise in the use of spray foam insulation in construction. Spray foam insulation varies from traditional insulation, such as fiberglass, in many respects. Fiberglass insulation is typically much cheaper than spray foam insulation; however, it is also less effective at insulating your home. Additionally, spray foaminsulation requires professional installation. Though spray foam insulation is on the rise, fiberglass is still the most common form of home insulation used today.

Legend Coatings and Insulation values the integrity of our work. We have extensive training when it comes to spray application. All of our applicators at Legend are trained and certified to industry standards. We do not stand alone when it comes to the building science behind our systems . We work hand in hand with Certified HVAC Contractors, Architects and Building Officials to combine our experience and expertise to find the best possible system to suite your needs and maximize your investment. Spray Coating
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others. Insulation Spray Coating
FIRESHELL® (F10E) is a proprietary non-flammable, intumescing (expands up to 2000%) interior coating that provides oxygen starvation to fire. It is a non-toxic, water based, drain safe, no fuming GREEN product. FIRESHELL® passes full scale room corner over foam, NFPA 286 and E84 class A certified. Meets requirements for 15 minute thermal barrier. It is a water-based one part coating system that comes white but can be tinted different colors. This coating can be top-coated with either latex or oil based coating. Insulation Spray Coating
Proper recordkeeping: One of the basic tenets of risk control is maintenance of updated health records of personnel handling spray paint products. Confidential data on biological monitoring[12] results must be appropriately kept.[13] Records of the schedule and result of testing procedures should also be kept. Some of the most important tests to be conducted on a regular basis are air quality testing, testing of pressure systems and electrical systems, and testing of compressor reservoir air filters. Coating Services

4 years ago I applied Gaco Roof, coats to an Office Building flat roof and have zero leaks since that time. This saved me $30,000 compared to having a new roof installed. The roof itself was only 7 years old when I applied Gaco Roof. but due to ponding water and harsh Florida heat and UV, the roof already looked shot and was leaking. I have now used Gaco Roof on 4 flat roofs to great results. I also tried big hardware store lower cost substitutes on 2 flat roofs. Those product utterly failed 1 to 2 years. Yes, I pressure washed my roofs clean before using Gaco Roof and followed their simple installation instructions. Excellent product. Insulation Spray Coating


With the increase in spray foaminsulation, many are wondering whether or not you should use a thermal or ignition barrier. Additionally, many are wondering if building codes require ignition or thermal barriers with spray foam insulation. The short answer is that you should use a thermal or ignition barrier, but the code may not necessarily require it. Building codes are often complicated, poorly written, poorly enforced, and up to interpretation by local code officials. This results in ambiguous requirements regarding spray foam insulation and fire protection. Spray Coating
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating
Another type of thermal barrier that can be used instead of prescriptive or approved equivalents is a barrier that has been tested as an alternate assembly. Alternate assembly methods are used to get approval for various types of intumescent coatings. In order for alternate assembly products to meet code, they must be installed and used in the exact same way that the alternate assembly was tested in the laboratory.
Fiberglass is the giant in the insulation industry, and the R rating to which it conforms is ingrained in the minds of contractors, builders, and code inspectors. Insulating ceramic coatings offer an alternative to traditional batt insulation. “Fiberglass insulation is tested and rated at 73 degrees Fahrenheit, which is the ideal temperature for fiberglass,” says Pritchett. Under harsher conditions, Pritchett suggests that fiberglass doesn’t perform as well as its ratings predict. Coating Services
Our elastomeric rubber coatings for metal roofs provide unmatched flexibility and resistance against harsh weather conditions. From tin roof sealant to corrugated and rusty metal roof sealants, our products are specially formulated for a wide variety of metal roof types. Check out our full selection of rubber coatings for metal roofs below, in addition to application instructions for the best results.
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine. Spray Coating
×