This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.  
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
Fiberglass is the giant in the insulation industry, and the R rating to which it conforms is ingrained in the minds of contractors, builders, and code inspectors. Insulating ceramic coatings offer an alternative to traditional batt insulation. “Fiberglass insulation is tested and rated at 73 degrees Fahrenheit, which is the ideal temperature for fiberglass,” says Pritchett. Under harsher conditions, Pritchett suggests that fiberglass doesn’t perform as well as its ratings predict. Coating Services
Mass-produced material is loaded on a conveyor belt where it is fed into one of these flatline machines. Flatline machines are designed to specifically paint material that is less than 4 inches (10 cm) thick and complex in shape, for example a kitchen cabinet door or drawer front. Spray guns are aligned above the material and the guns are in motion in order to hit all the grooves of the material. The guns can be moved in a cycle, circle, or can be moved back and forth in order to apply paint evenly across the material. Flatline systems are typically large and can paint doors, kitchen cabinets, and other plastic or wooden products. Coating Services

High volume low pressure (HVLP) is similar to a conventional spray gun using a compressor to supply the air, but the spray gun itself requires a lower pressure (LP). A higher volume (HV) of air is used to aerosolise and propel the paint at lower air pressure. The result is a higher proportion of paint reaching the target surface with reduced overspray, materials consumption, and air pollution. A regulator is often required so that the air pressure from a conventional compressor can be lowered for the HVLP spray gun. Alternatively a turbine unit (commonly containing a vacuum cleaner derived motor) can be used to propel the air without the need for an air line running to the compressor. Coating Services
After researching this, Im curious about a method called poor mans sprayfoam where foamboard is cut to size between studs and sprayfoamed around the perimeter. Aside from the labour doing the job yourself, the cost seems comparable, is one better than the other? What about the quality of the canned sprayfoam around the perimeter? When i see sprayfoam done, it is never a full depth of the studs, so you would get 2.5-3 inches in a 3.5" (2x4) wall. Any thoughts? 
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Spray Coating

We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend? Insulation Spray Coating


Legend Coatings and Insulation values the integrity of our work. We have extensive training when it comes to spray application. All of our applicators at Legend are trained and certified to industry standards. We do not stand alone when it comes to the building science behind our systems . We work hand in hand with Certified HVAC Contractors, Architects and Building Officials to combine our experience and expertise to find the best possible system to suite your needs and maximize your investment.
The process typically operates at 39–120 °C to avoid thermal damage. It can induce non-thermally activated surface reactions, causing surface changes which cannot occur with molecular chemistries at atmospheric pressure. Plasma processing is done in a controlled environment inside a sealed chamber at a medium vacuum, around 13–65 Pa. The gas or mixture of gases is energized by an electrical field from DC to microwave frequencies, typically 1–500 W at 50 V. The treated components are usually electrically isolated. The volatile plasma by-products are evacuated from the chamber by the vacuum pump, and if necessary can be neutralized in an exhaust scrubber.
Are you tired of dealing with insulation jackets or insulation covers that don’t fit? Spray-on thermal insulating coatings by Synavax™ fit any shape of equipment and do not require any exterior jacketing. You can spray apply this technology easily while equipment is in-service and our concentrated insulation coatings will work diligently for 5-10 years or more without degrading. Spray Coating Services
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating Services
Estimated Coverage: Standard product coverage on a smooth surface for Ames® Super Primer™ is 200 sq. ft. per gallon per coat and the product coverage rate for Ames® Maximum Stretch® and Ames® Iron Coat® is 100 sq. ft. per gallon per coat. Rough or uneven surfaces may require additional product. More than one coat of Ames® Maximum Stretch® or Ames® Iron Coat® is recommended. More coats equal longer life. Coating Services

Independent reviews at Site Jabber. Site Jabber is the leading community of online business reviewers. The community helps consumers find great online business and avoid scams. The community has grown to over 850,000 members and has reviewed over 58,000 online businesses. Site Jabber was developed in part with a grant from the National Science Foundation. Spray Coating Services
Legend Coatings & Insulation, LLC has set the foundation for all insulating and coating applications. With over 12 years experience in the field we have established the dynamics uniquely behind each of our systems. Our dual proportional coatings rig allows us mobilization with the capacity to be self sufficient and finishing your project on time and on budget.
Condensation - It can seem like a tropical rain forest inside an unprotected metal building. It's worse on those days where there is a greater contrast between temperatures at night vs. day. The morning sun hitting the cool sheeting will create a drip. A temperature difference between outside and inside your building creates condensation - Similar to what happens when you leave a cold can of beer outside on a hot day. 
As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor. Spray Coating
In cold spraying, particles are accelerated to very high speeds by the carrier gas forced through a converging–diverging de Laval type nozzle. Upon impact, solid particles with sufficient kinetic energy deform plastically and bond mechanically to the substrate to form a coating. The critical velocity needed to form bonding depends on the material's properties, powder size and temperature. Metals, polymers, ceramics, composite materials and nanocrystalline powders can be deposited using cold spraying.[4] Soft metals such as Cu and Al are best suited for cold spraying, but coating of other materials (W, Ta, Ti, MCrAlY, WC–Co, etc.) by cold spraying has been reported.[1]
HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1] Spray Coating

Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code. Insulation Spray Coating
You like to make the tough call and enjoy having the authority to make decisions in the best interests of your customers. At PPG Coatings Services, we value those traits because our industry is constantly changing. In our business, you can't always wait for a decision, a change or a result. We constantly invest in our business, but we also invest in you, providing the skills, technical knowledge and independence you need to create loyal, satisfied and successful customers. Spray Coating Services

Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
A rule of thumb puts two thirds of the coating on the substrate and one third in the air. True HVLP guns use 8–20 cfm (13.6–34 m3/h), and an industrial compressor with a minimum of 5 horsepower (3.7 kW) output is required. HVLP spray systems are used in the automotive, decorative, marine, architectural coating, furniture finishing, scenic painting, and cosmetic industries. Spray Coating
×