One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up. Spray Coating Services


This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers.
Introducing Mothers CMX Ceramic Spray Coating, an affordable, user-friendly, professional grade, ultra-durable, super-hydrophobic protection formula. Just spray on and wipe off, with this game-changing SiO2 (Silicon Dioxide) and TiO2 (Titanium Dioxide) blend. This powerhouse combo provides ultra long-term protection from the elements and relentless water beading, without sacrificing true optical clarity, extreme depth and that signature ceramic glass-like liquid-gloss appearance. Use as a stand-alone product, or as a booster over your existing sealant or ceramic coating. Washing and caring for your vehicle has never been easier. Cures in 24 hours (do not get vehicle wet during curing period). Spray Coating Services
Spray foam insulation is a great product. Homes insulated with it can be some of the most efficient and comfortable homes built. I've been in plenty of these homes and can tell you that when spray foam is installed properly, they outperform 99% of fiberglass batt-insulated, stick-built homes. (I can also tell you that 73% of all statistics are made up on the spot, so please don't ask for documentation of that statistic.)
As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor.
The second type of barrier that prevents insulation from catching fire is called the ignition barrier. Ignition barriers are a lower standard to meet than a thermal barrier. Additionally, several different materials can meet the definition of an ignition barrier. Now that we have established the code jargon for spray foam barriers, we can look at each type in detail.
The Rubberseal creates a coat that can efficiently reflect heat off the roofs of buildings. It is Energy Star rated, which means it’s friendly to the environment.The spread rate of this product is 60 square feet per gallon at 20 imperial mils. It dries in 2 hours but takes 72 hours to get fully cured. Check the weather forecast before you apply it. Spray Coating Services
This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers. Coating Services
The deposition efficiency is typically low for alloy powders, and the window of process parameters and suitable powder sizes is narrow. To accelerate powders to higher velocity, finer powders (<20 micrometers) are used. It is possible to accelerate powder particles to much higher velocity using a processing gas having high speed of sound (helium instead of nitrogen). However, helium is costly and its flow rate, and thus consumption, is higher. To improve acceleration capability, nitrogen gas is heated up to about 900 °C. As a result, deposition efficiency and tensile strength of deposits increase.[1]
The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Spray Coating Services
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
If you're plagued with quality problems caused by uneven application of coatings or waste of costly coatings due to over-application, take a close look at our products for precision coating. You will find a wide range of nozzles, standard and heated spray headers and automated spray systems to apply all types of coatings – including thick slurries, chocolate, viscous oils and more – uniformly with minimal waste.
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Mascoat is a great alternative to conventional insulation materials, including cellular glass, perlite, mineral wool, fiberglass, urethane & closed cell foam and calcium silicate. Mascoat coatings are lighter than traditional insulation, reducing bulk in your structure. Mascoat also requires much less maintenance than conventional insulation, which can ultimately save you time and money. Want to get started with Mascoat? Request more information today.

Health monitoring: In order to avoid development of illnesses associated with exposure to isocyanates, health authorities recommend that people who use spray paint products that contain the substance provide a urine sample after a work shift at least once a year, with high frequencies in first few months on the job. A urine sample with ascertain levels of exposure, not the presence of disease associated with harmful chemicals. Spray Coating Services
Since our founding in 1973, Dal-Bac Manufacturing Co., Inc. has grown and expanded to become one of the premier providers of coating services to customers in a diverse range of industries. We are capable of applying both solvent and water-borne coatings to a wide variety of substrates, including fabrics, films, foams, and papers. Our capabilities include both knife-over-roll and Meyer rod coating methods for roll goods up to 61” in width. With our custom built equipment, we process materials accurately and cost-effectively.
I applied the Gaco 100% Silicone Roof coating to a slightly-sloped, metal porch roof.  My leaks have stopped, and it looks like they are gone for good.  I followed the instructions, and it appears the product made a perfect bond to the roof.  What a terrific product!  I'm glad I made this purchase, and that I didn't settle for a cheap, metal coating from the local outlet store. Coating Services
The second type of barrier that prevents insulation from catching fire is called the ignition barrier. Ignition barriers are a lower standard to meet than a thermal barrier. Additionally, several different materials can meet the definition of an ignition barrier. Now that we have established the code jargon for spray foam barriers, we can look at each type in detail.
As discussed, many closed cell (and even some open cell) foam sprays do not need additional layers to serve as an ignition barrier. It is possible to use these spray foams, and leave them exposed in attics and crawl spaces. Additionally, you can use alternate assembly spray foams with intumescent coats and leave them exposed in an attic or crawl space without the use of an ignition barrier. In order for these methods to be accepted by code officials, the spray foammust be sprayed in the same exact manner they were in the assembly test in the laboratory.
Blocking heat buildup is a complicated task. Heat comes in three forms: ultra-violet (UV), visible light, and infrared (IR). A quality ceramic coating will block all three, especially IR, which is responsible for roughly 57 percent of heat load on a building. “Some ceramic paints claim to block all heat caused by UV,” says Pritchett, “but UV only accounts for three percent of heat load on a building.” Spray Coating Services
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
Whether you work on frame-up restorations in your garage, or projects like refinishing wheels, interior upgrades or maintaining the appearance of your everyday ride, Dupli-Color wants to be there with you. We have a heritage of providing only the best in automotive products since 1938, when we first started selling touch-up paint. This marked the beginning of “innovative firsts” which continues today with the automotive aftermarket’s largest array of DIY paints, primers and coatings.
Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include:
With the increase in spray foaminsulation, many are wondering whether or not you should use a thermal or ignition barrier. Additionally, many are wondering if building codes require ignition or thermal barriers with spray foam insulation. The short answer is that you should use a thermal or ignition barrier, but the code may not necessarily require it. Building codes are often complicated, poorly written, poorly enforced, and up to interpretation by local code officials. This results in ambiguous requirements regarding spray foam insulation and fire protection. Spray Coating
Our elastomeric rubber coatings for metal roofs provide unmatched flexibility and resistance against harsh weather conditions. From tin roof sealant to corrugated and rusty metal roof sealants, our products are specially formulated for a wide variety of metal roof types. Check out our full selection of rubber coatings for metal roofs below, in addition to application instructions for the best results. Coating Services
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. Spray Coating Services
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier. Spray Coating
×