Building code uses two different terms to describe barriers that protect insulation and prevent them from catching fire. The first is called a thermal barrier, which is a poorly chosen word. Typically, scientists and builders refer to insulation as a thermal barrier. Most people would think of a thermal barrier as something that keeps heat in. However, in building code, thermal barrier essentially refers to 1/2-inch drywall, though the definition can get more complicated than that.
One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up. Spray Coating Services
Mascoat is a great alternative to conventional insulation materials, including cellular glass, perlite, mineral wool, fiberglass, urethane & closed cell foam and calcium silicate. Mascoat coatings are lighter than traditional insulation, reducing bulk in your structure. Mascoat also requires much less maintenance than conventional insulation, which can ultimately save you time and money. Want to get started with Mascoat? Request more information today.
Legend Coatings & Insulation, LLC has set the foundation for all insulating and coating applications. With over 12 years experience in the field we have established the dynamics uniquely behind each of our systems. Our dual proportional coatings rig allows us mobilization with the capacity to be self sufficient and finishing your project on time and on budget. Coating Services
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet. Coating Services

Krylon offers easy-to-use, quality products to help you tackle just about every project, indoors and out. Renew an old grill with Krylon High Heat Max, reinvent your home with our decorative paints or touch up scuffs with Krylon Automotive spray paint. Pros also trust Krylon to get the job done with high-durability enamels and more. Whatever the task, Krylon has a solution.
The average price to cover 200 square feet with a foam insulation kit will run between $300 and $600 (about two to three kits). Inside these kits is something called Icynene, a foam made from two liquids that are heated and pushed through a gun on the can. When Icynene is released, it expands up to 100 times its size as it hits the surface area you're covering. These can contain a lot of gasses, making its installation a dangerous process. Even low-pressure sprayers can be harmful to homeowners' health.
Whether or not an intumescent coating, or even a thermal or ignition barrier, is needed often depends on the type of spray foaminsulation that builders use. Many closed cell foam sprays are already sufficiently fire resistant and need no additional barriers. Ultimately, whether or not you need an ignition barrier or thermal barrier varies depending on location and materials. You should check with your local code official to ensure that your insulation work is up to code.
Thermal spraying can provide thick coatings (approx. thickness range is 20 microns to several mm, depending on the process and feedstock), over a large area at high deposition rate as compared to other coating processes such as electroplating, physical and chemical vapor deposition. Coating materials available for thermal spraying include metals, alloys, ceramics, plastics and composites. They are fed in powder or wire form, heated to a molten or semimolten state and accelerated towards substrates in the form of micrometer-size particles. Combustion or electrical arc discharge is usually used as the source of energy for thermal spraying. Resulting coatings are made by the accumulation of numerous sprayed particles. The surface may not heat up significantly, allowing the coating of flammable substances. Spray Coating Services
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria. Insulation Spray Coating
I guess I'm saying all of these products are good, they will complement the work you do on your car if you're willing to put the time into it. And it will make it easier to maintain the next time you wash your car. If you don't clay and polish your car, don't expect super slick results. If you put the work into it, when you spray the car down with water, use a soap wash, rinseless wash, it will still shiny after you put any product on it! Don't get caught up in the SIO2 hype, just spend what you're willing to pay for the product. You'll be happy with any product.
Our insulation and protective coatings are designed for the harshest outdoor and offshore environments, such as those experienced by our customer Sinopec on their offshore fuel oil storage tanks, black liquor tanks in pulp and paper mills like those of Weyerhaeuser, and even in the frigid cold of Alaska where our thermal barrier insulation coatings helped insulate steam and water pipes for the U.S. Army. Our customers choose Synavax™ industrial and building insulating coating solutions because of the superior combined energy savings, stay clean, and asset protection benefits. Spray Coating Services
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
×