Since our founding in 1973, Dal-Bac Manufacturing Co., Inc. has grown and expanded to become one of the premier providers of coating services to customers in a diverse range of industries. We are capable of applying both solvent and water-borne coatings to a wide variety of substrates, including fabrics, films, foams, and papers. Our capabilities include both knife-over-roll and Meyer rod coating methods for roll goods up to 61” in width. With our custom built equipment, we process materials accurately and cost-effectively.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet. Insulation Spray Coating
While intumescent coating can be used instead of an ignition barrier or thermal barrier in some cases, the coating itself is not technically either. It does prevent or slow fires, so it has been approved to be used in conjunction with spray foaminsulation as an alternate assembly. The fact that it qualifies as an alternate assembly means that it can be used instead of a thermal barrier or ignition barrier. Coating Services

The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
If you're plagued with quality problems caused by uneven application of coatings or waste of costly coatings due to over-application, take a close look at our products for precision coating. You will find a wide range of nozzles, standard and heated spray headers and automated spray systems to apply all types of coatings – including thick slurries, chocolate, viscous oils and more – uniformly with minimal waste. Spray Coating
Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install. Spray Coating Services
Thermal barriers come in the form of 1/2-inch gypsum drywall or any material that is proven to have an equal fire resistance to gypsum wallboard. Additionally, alternate assemblies can be used if they have been tested in a laboratory and approved. Ignition barriers are a lower standard to meet, and can be satisfied with a number of different materials. Like thermal barriers, they can be substituted with equivalent fire resistant materials and alternate assemblies, such as an intumescent coating. Coating Services
Please Note: Prices, promotions, styles and availability may vary by store and online. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. This inventory may include a store display unit. Online orders and products purchased in-store qualify for rebate redemption. Mail-in Rebate is in the form of merchandise credit check, valid in-store only. Merchandise credit check is not valid towards purchases made on MENARDS.COM®. By submitting this rebate form, you agree to resolve any disputes related to rebate redemption by binding arbitration and you waive any right to file or participate in a class action. Terms and conditions available at www.rebateinternational.com®

Estimated Coverage: Standard product coverage on a smooth surface for Ames® Super Primer™ is 200 sq. ft. per gallon per coat and the product coverage rate for Ames® Maximum Stretch® and Ames® Iron Coat® is 100 sq. ft. per gallon per coat. Rough or uneven surfaces may require additional product. More than one coat of Ames® Maximum Stretch® or Ames® Iron Coat® is recommended. More coats equal longer life.
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine. Coating Services
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet. Insulation Spray Coating
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level. Insulation Spray Coating
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. Spray Coating
×