I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. Spray Coating Services

The atomization of molten materials produces a large amount of dust and fumes made up of very fine particles (ca. 80–95% of the particles by number <100 nm).[8] Proper extraction facilities are vital, not only for personal safety, but to minimize entrapment of re-frozen particles in the sprayed coatings. The use of respirators, fitted with suitable filters, is strongly recommended, where equipment cannot be isolated.[8] Certain materials offer specific known hazards:[6] Insulation Spray Coating
The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important. Spray Coating Services
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Insulation Spray Coating
I applied CMX on my wife's car and my car and had odd results. See pic. I ended up with little white beads that formed when I sprayed CMX on car, wiped it to a haze, but not completely off. After about 2 minutes I then began to wipe CMX until the haze was gone. However, oddly, after letting the product dry (but not yet wiping completely off) it began to form white little beads (possibly residual). What a pain as these beads landed in all the window crevices, etc. It's like when you have a bad wax that leaves dust. I had to use a can of compressed air to wipe the bead out of the crevices. I was thinking that allowing it to haze would allow CMX to bond to the paint better. After getting the beads cleaned up I tested again and spray CMX on, then wiped completely dry. No beads. Coating Services
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. Coating Services
New fire safety tests for intumescent coatings were created by code officials and the spray foam industry, and many manufacturers found their closed cell spray foams could pass the test without any intumescent coating. Some open cell spray foam can pass the fire tests without an intumescent coating, but most still require the coating. Approved closed cell spray foams do not need the ignition barriers discussed above, which can make the job easier for builders. Coating Services

During the 1980s, a class of thermal spray processes called high velocity oxy-fuel spraying was developed. A mixture of gaseous or liquid fuel and oxygen is fed into a combustion chamber, where they are ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging–diverging nozzle and travels through a straight section. The fuels can be gases (hydrogen, methane, propane, propylene, acetylene, natural gas, etc.) or liquids (kerosene, etc.). The jet velocity at the exit of the barrel (>1000 m/s) exceeds the speed of sound. A powder feed stock is injected into the gas stream, which accelerates the powder up to 800 m/s. The stream of hot gas and powder is directed towards the surface to be coated. The powder partially melts in the stream, and deposits upon the substrate. The resulting coating has low porosity and high bond strength.[1] Spray Coating Services
I applied CMX on my wife's car and my car and had odd results. See pic. I ended up with little white beads that formed when I sprayed CMX on car, wiped it to a haze, but not completely off. After about 2 minutes I then began to wipe CMX until the haze was gone. However, oddly, after letting the product dry (but not yet wiping completely off) it began to form white little beads (possibly residual). What a pain as these beads landed in all the window crevices, etc. It's like when you have a bad wax that leaves dust. I had to use a can of compressed air to wipe the bead out of the crevices. I was thinking that allowing it to haze would allow CMX to bond to the paint better. After getting the beads cleaned up I tested again and spray CMX on, then wiped completely dry. No beads.
In addition, it's difficult for an inexperienced installer to evenly spread the insulation foam over a surface. Miissing spots can leave holes and gaps for cold air to get through. Proceed with this project yourself only if you're doing a small insulation project -- such as installing foam in a crawl space or around your plumbing. Leave larger projects like the attic, basement or garage to the professional insulation contractors. Insulation professionals have the tools, equipment and background knowledge necessary. Moreover, they know how to accurately price insulation, whereas you could inaccurately budget for a DIY project and end up paying significantly more. Don't take the medical, physical or financial risks that come with pursuing this as a DIY project unless you're absolutely certain you have the skills.
In addition, it's difficult for an inexperienced installer to evenly spread the insulation foam over a surface. Miissing spots can leave holes and gaps for cold air to get through. Proceed with this project yourself only if you're doing a small insulation project -- such as installing foam in a crawl space or around your plumbing. Leave larger projects like the attic, basement or garage to the professional insulation contractors. Insulation professionals have the tools, equipment and background knowledge necessary. Moreover, they know how to accurately price insulation, whereas you could inaccurately budget for a DIY project and end up paying significantly more. Don't take the medical, physical or financial risks that come with pursuing this as a DIY project unless you're absolutely certain you have the skills. Coating Services
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard.
The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important.

When using this roof coating, two coats are required. It doesn’t take much time to apply the coating. If the weather is not humid, the coating will take only a few hours to get completely dry in full sun.This coating can go over and hold strong on the sealing tapes. This feature helps you to restore your roof to brand new. It may save thousands of dollars from replacing your old roof. Spray Coating
×