Spray painting poses health hazards that affect the respiratory, nervous, and circulatory systems. Similarly, using solvents to clean one's hands of paint marks and residue may cause skin irritation or even more serious issues since many are carcinogenic or neurotoxic. There are risks involved in working with substances such as paint and thinner, which contain compounds that are potentially harmful to health, or even fatal.[9] Insulation Spray Coating
These operate connected to a high pressure pump commonly found using 300 to 7,500 pounds per square inch (2,100–51,700 kPa) pressure to atomize the coating, using different tip sizes to achieve desired atomization and spray pattern size. This type of system is used by contract painters to paint heavy duty industrial, chemical and marine coatings and linings. Coating Services
For over a decade, Synavax™ has served as the preferred industrial thermal barrier insulation, energy saving, surface protection and asset protection coating, meeting the needs of multiple industries around the world, including pulp and paper manufacturing, food and beverage manufacturing, U.S. military, oil and gas, textile manufacturing and many others.
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
Electrostatic painting was first patented in the U.S. by Harold Ransburg in the late 1940s. Harold Ransburg founded Ransburg Electrostatic Equipment and discovered that electrostatic spray painting was an immediate success as manufacturers quickly perceived the substantial materials savings that could be achieved. In electrostatic spray painting or powder coating, the atomized particles are made to be electrically charged, thereby repelling each other and spreading themselves evenly as they exit the spray nozzle. The object being painted is charged oppositely or grounded. The paint is then attracted to the object giving a more even coat than wet spray painting, and also greatly increasing the percentage of paint that sticks to the object. This method also means that paint covers hard to reach areas. The whole may then be baked to properly attach the paint: the powder turns into a type of plastic. Car body panels and bike frames are two examples where electrostatic spray painting is often used. Coating Services
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.

Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Coating Services
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Due to a wide range of nozzle shapes and sizes, the consistency of the paint can be varied. The shape of the workpiece and the desired paint consistency and pattern are important factors when choosing a nozzle. The three most common nozzles are the full cone, hollow cone, and flat stream.[6] There are two types of air-gun spraying processes. In a manual operation method the air-gun sprayer is held by a skilled operator, about 6 to 10 inches (15–25 cm) from the object, and moved back and forth over the surface, each stroke overlapping the previous to ensure a continuous coat.[7] In an automatic process the gun head is attached to a mounting block and delivers the stream of paint from that position. The object being painted is usually placed on rollers or a turntable to ensure overall equal coverage of all sides.
Heat Shield™ EPX-H2O is a complete thermal barrier insulation system for pipes, tanks, and other industrial equipment and can provide 100% insulation coverage of all odd-shaped configurations – no more expensive insulation jackets or insulated covers needed. This next generation heat insulating coating has you covered for all types of directives – energy savings, safe touch for employee safety, heat radiation reduction, and asset protection from chemicals and corrosion. Don’t leave uninsulated areas in your pipe and tank insulation system that will lead to heat and energy loss. Instead use an easy spray-on solution that can coat, protect, and insulate your entire heat process system, including valves, pipes, tanks, boilers, heat exchangers, and more. Synavax™ thermal insulating and protective coating is a technology you can trust to perform consistently for 10 years or more. Spray Coating
The detonation gun consists of a long water-cooled barrel with inlet valves for gases and powder. Oxygen and fuel (acetylene most common) are fed into the barrel along with a charge of powder. A spark is used to ignite the gas mixture, and the resulting detonation heats and accelerates the powder to supersonic velocity through the barrel. A pulse of nitrogen is used to purge the barrel after each detonation. This process is repeated many times a second. The high kinetic energy of the hot powder particles on impact with the substrate results in a buildup of a very dense and strong coating. Coating Services
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Spray Coating
×