Thermal spraying need not be a dangerous process, if the equipment is treated with care, and correct spraying practices are followed. As with any industrial process, there are a number of hazards, of which the operator should be aware, and against which specific precautions should be taken. Ideally, equipment should be operated automatically, in enclosures specially designed to extract fumes, reduce noise levels, and prevent direct viewing of the spraying head. Such techniques will also produce coatings that are more consistent. There are occasions when the type of components being treated, or their low production levels, requires manual equipment operation. Under these conditions, a number of hazards, peculiar to thermal spraying, are experienced, in addition to those commonly encountered in production or processing industries.[6]
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary. Spray Coating
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet. Coating Services
Tools: Ames® premium elastomeric roof coatings can be applied with a paint brush, a push broom, a paint roller or a commercial/industrial airless sprayer. In addition, you may need Ames® Peel & Stick™ Seam Tape, a pair of scissors and utility knife. For larger commercial jobs, we recommend a commercial/industrial airless sprayer. Call 888-345-0809 with questions or click here for sprayer specifications. Spray Coating Services
Ignition barriers include six permissible materials. An ignition barrier can be 1/4-inch plywood or structural panels, 1 1/2-inch mineral fiber insulation, 1/4 inch hardboard, corrosion resistant steel at least .016 inches thick, 3/8-inch gypsum board, or 3/8- inch particle board. These sizes are the minimum; code officials will approve of thicker versions of any of these six materials as ignition barriers. Like thermal barriers, equivalent materials that have been shown to have equivalent fire resistance are acceptable. Additionally, an alternate assembly can be used if the assembly has been tested by a laboratory and meets certain criteria.
Health monitoring: In order to avoid development of illnesses associated with exposure to isocyanates, health authorities recommend that people who use spray paint products that contain the substance provide a urine sample after a work shift at least once a year, with high frequencies in first few months on the job. A urine sample with ascertain levels of exposure, not the presence of disease associated with harmful chemicals. Spray Coating Services

Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.
Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below). Coating Services
In cold spraying, particles are accelerated to very high speeds by the carrier gas forced through a converging–diverging de Laval type nozzle. Upon impact, solid particles with sufficient kinetic energy deform plastically and bond mechanically to the substrate to form a coating. The critical velocity needed to form bonding depends on the material's properties, powder size and temperature. Metals, polymers, ceramics, composite materials and nanocrystalline powders can be deposited using cold spraying.[4] Soft metals such as Cu and Al are best suited for cold spraying, but coating of other materials (W, Ta, Ti, MCrAlY, WC–Co, etc.) by cold spraying has been reported.[1]
Introducing Mothers CMX Ceramic Spray Coating, an affordable, user-friendly, professional grade, ultra-durable, super-hydrophobic protection formula. Just spray on and wipe off, with this game-changing SiO2 (Silicon Dioxide) and TiO2 (Titanium Dioxide) blend. This powerhouse combo provides ultra long-term protection from the elements and relentless water beading, without sacrificing true optical clarity, extreme depth and that signature ceramic glass-like liquid-gloss appearance. Use as a stand-alone product, or as a booster over your existing sealant or ceramic coating. Washing and caring for your vehicle has never been easier. Cures in 24 hours (do not get vehicle wet during curing period).
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine.
If you are looking for the best roof coating, you should try the Heng’s. This product is protective, and can seal vents, air conditioners and more. And it’s budget friendly, we believe you will like it.This roof coating is perfect for RV rubber roof, because it can expand and contract with the roof. It can offer the best protection for the roof in any weather condition.

Condensation - It can seem like a tropical rain forest inside an unprotected metal building. It's worse on those days where there is a greater contrast between temperatures at night vs. day. The morning sun hitting the cool sheeting will create a drip. A temperature difference between outside and inside your building creates condensation - Similar to what happens when you leave a cold can of beer outside on a hot day.  Insulation Spray Coating


Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Spray Coating

FIRESHELL® (F10E) is a proprietary non-flammable, intumescing (expands up to 2000%) interior coating that provides oxygen starvation to fire. It is a non-toxic, water based, drain safe, no fuming GREEN product. FIRESHELL® passes full scale room corner over foam, NFPA 286 and E84 class A certified. Meets requirements for 15 minute thermal barrier. It is a water-based one part coating system that comes white but can be tinted different colors. This coating can be top-coated with either latex or oil based coating. Insulation Spray Coating
Wire arc spray is a form of thermal spraying where two consumable metal wires are fed independently into the spray gun. These wires are then charged and an arc is generated between them. The heat from this arc melts the incoming wire, which is then entrained in an air jet from the gun. This entrained molten feedstock is then deposited onto a substrate with the help of compressed air. This process is commonly used for metallic, heavy coatings.[1]
Thermal barriers are defined in building code as 1/2-inch gypsum wallboard or any material that is as equally fire resistant as 1/2-inch gypsum wallboard. The gypsum wallboard is known as a prescriptive thermal barrier. Materials are tested in a 15-minute fire test in order to determine whether or not they are equal in fire resistance to the 1/2-inch gypsum wallboard. If they are, then they can be used and counted as the equivalent of gypsum wallboard. Coating Services
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think. Spray Coating
×