To say spray foam insulation has become popular in green building over the past decade is like saying Peyton Manning is a good quarterback. It's an understatement. Although it's certainly not used in every green building project, it's become one of the most popular ways to build an air-tight house. In the early days, building codes hadn't caught up with how best to use this material, but that's changing. Change begets confusion, though, and the requirements for thermal and ignition barriers are one area where there's a lot of that.
Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below). Coating Services
In classical (developed between 1910 and 1920) but still widely used processes such as flame spraying and wire arc spraying, the particle velocities are generally low (< 150 m/s), and raw materials must be molten to be deposited. Plasma spraying, developed in the 1970s, uses a high-temperature plasma jet generated by arc discharge with typical temperatures >15,000 K, which makes it possible to spray refractory materials such as oxides, molybdenum, etc.[1]
As an ISO certified company, we have a robust quality management system to ensure that everything, from incoming raw materials to the final product, meets or exceeds customer requirements. We measure and inspect characteristics such as coating thickness, coating weight, residual solvents/water, and bond strength to ensure your products perform as expected. Agile and efficient, we can process most work within a two- to four-week timeframe and have the flexibility to manage rush orders for situations where time is a critical factor. Spray Coating Services
This product has nice UV resistance, thus to reduce the temperature of your roof. It also resists cracking and withstands impact, providing a durable barrier for the roof.This product is non-polluting and non-toxic, being safe for the environment and your health. It’s easy to apply, and one gallon of this roof coating can cover up to 200 square feet of surface area. Spray Coating
I applied CMX on my wife's car and my car and had odd results. See pic. I ended up with little white beads that formed when I sprayed CMX on car, wiped it to a haze, but not completely off. After about 2 minutes I then began to wipe CMX until the haze was gone. However, oddly, after letting the product dry (but not yet wiping completely off) it began to form white little beads (possibly residual). What a pain as these beads landed in all the window crevices, etc. It's like when you have a bad wax that leaves dust. I had to use a can of compressed air to wipe the bead out of the crevices. I was thinking that allowing it to haze would allow CMX to bond to the paint better. After getting the beads cleaned up I tested again and spray CMX on, then wiped completely dry. No beads.

Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close Spray Coating

Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier.
I installed Prodex in my 40'x40'x14' Steel garage when I bought the building it came with the 4" thick 6' wide white vinyl that was hard to work with because of it's weight and bulkiness. The weather was rainy and it was just my wife and I installing the insulation and steel sheeting. Trying to find something easier to work with I found your product I ordered enough to line the entire garage it was grate to work with. When the garage door company cam to install the garage doors on January 02/2010 the temperature outside was 10 degrees and windy. After they had the door tracks fastened enough to hold the doors in place they light there portable gas salamander I was impressed with how quickly it warmed to 40 degrees and healed the heat after they turned it off.

Charles: That photo is closed-cell SPF, and it's not sprayed perfectly uniformly. As long as it has the minimum thickness required (3" on a ceiling here in the Atlanta area), it should be fine. I've discussed some problems with SPF installations in the articles listed in the Related Articles section above. This photo is from about 10 years ago, though, and has no ignition barrier.   Insulation Spray Coating
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else.  Spray Coating
The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  
In order to fulfill the requirements for an ignition barrier, most builders will choose to install a prescriptive ignition barrier such as mineral fiber insulation, install cellulose insulation, or install an approved alternate assembly of spray foam insulation coated with an intumescent coating. Recently, builders have begun using spray foam insulation that passes fire safety tests on their own, without any protective barriers or intumescent coatings.
Blocking heat buildup is a complicated task. Heat comes in three forms: ultra-violet (UV), visible light, and infrared (IR). A quality ceramic coating will block all three, especially IR, which is responsible for roughly 57 percent of heat load on a building. “Some ceramic paints claim to block all heat caused by UV,” says Pritchett, “but UV only accounts for three percent of heat load on a building.” Coating Services

HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1] Spray Coating
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.

This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.  
Mass-produced material is loaded on a conveyor belt where it is fed into one of these flatline machines. Flatline machines are designed to specifically paint material that is less than 4 inches (10 cm) thick and complex in shape, for example a kitchen cabinet door or drawer front. Spray guns are aligned above the material and the guns are in motion in order to hit all the grooves of the material. The guns can be moved in a cycle, circle, or can be moved back and forth in order to apply paint evenly across the material. Flatline systems are typically large and can paint doors, kitchen cabinets, and other plastic or wooden products. Spray Coating Services
I finally completed my 60" X 42" steel building using your insulation between the steel studs and the metal sheeting. I was amazed at the temperature difference. The metal is not allowed to adversely heat the building and the temperature is cooler than under a shade tree because of the breeze created within the door openings. The reflective foil also provides a tremendous amount of light reflection inside the building creating a very bright look inside. I am amazed and presently surprised that the thin foil actually worked so well.
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating
I have learned to like this product by using a different method of application. Rather than spraying the sealant directly on the paint surface, I've learned that applying it to a MF applicator pad then spreading evenly and buffing off works best to avoid the crystal dusting. The durability is very impressive for a spray sealant. After 1 month, the water beading is still 100% active and the added gloss is still present.
Estimated Coverage: Standard product coverage on a smooth surface for Ames® Super Primer™ is 200 sq. ft. per gallon per coat and the product coverage rate for Ames® Maximum Stretch® and Ames® Iron Coat® is 100 sq. ft. per gallon per coat. Rough or uneven surfaces may require additional product. More than one coat of Ames® Maximum Stretch® or Ames® Iron Coat® is recommended. More coats equal longer life.
Since our founding in 1973, Dal-Bac Manufacturing Co., Inc. has grown and expanded to become one of the premier providers of coating services to customers in a diverse range of industries. We are capable of applying both solvent and water-borne coatings to a wide variety of substrates, including fabrics, films, foams, and papers. Our capabilities include both knife-over-roll and Meyer rod coating methods for roll goods up to 61” in width. With our custom built equipment, we process materials accurately and cost-effectively. Insulation Spray Coating
Fiberglass is the giant in the insulation industry, and the R rating to which it conforms is ingrained in the minds of contractors, builders, and code inspectors. Insulating ceramic coatings offer an alternative to traditional batt insulation. “Fiberglass insulation is tested and rated at 73 degrees Fahrenheit, which is the ideal temperature for fiberglass,” says Pritchett. Under harsher conditions, Pritchett suggests that fiberglass doesn’t perform as well as its ratings predict.
The Barrier product family is EPS foam under The Barrier product family is EPS foam under slab insulation and vapor retarder in a roll designed to insulate radiant heating projects from heat loss and retard moisture migration through concrete. The core of the product is made of flexible recyclable expanded polystyrene that provides excellent insulation characteristics that are ...  More + Product Details Close
Like HVLP, low volume low pressure (LVLP) spray guns also operate at a lower pressure (LP), but they use a low volume (LV) of air when compared to conventional and HVLP equipment. This is a further effort at increasing the transfer efficiency (amount of coating that ends up on the target surface) of spray guns, while decreasing the amount of compressed air consumption. Insulation Spray Coating

One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up. Spray Coating Services
In plasma spraying process, the material to be deposited (feedstock) — typically as a powder, sometimes as a liquid,[2] suspension [3] or wire — is introduced into the plasma jet, emanating from a plasma torch. In the jet, where the temperature is on the order of 10,000 K, the material is melted and propelled towards a substrate. There, the molten droplets flatten, rapidly solidify and form a deposit. Commonly, the deposits remain adherent to the substrate as coatings; free-standing parts can also be produced by removing the substrate. There are a large number of technological parameters that influence the interaction of the particles with the plasma jet and the substrate and therefore the deposit properties. These parameters include feedstock type, plasma gas composition and flow rate, energy input, torch offset distance, substrate cooling, etc. Spray Coating Services

Are you tired of dealing with insulation jackets or insulation covers that don’t fit? Spray-on thermal insulating coatings by Synavax™ fit any shape of equipment and do not require any exterior jacketing. You can spray apply this technology easily while equipment is in-service and our concentrated insulation coatings will work diligently for 5-10 years or more without degrading.
Are you tired of dealing with insulation jackets or insulation covers that don’t fit? Spray-on thermal insulating coatings by Synavax™ fit any shape of equipment and do not require any exterior jacketing. You can spray apply this technology easily while equipment is in-service and our concentrated insulation coatings will work diligently for 5-10 years or more without degrading. Spray Coating Services

Legend Coatings & Insulation, LLC has set the foundation for all insulating and coating applications. With over 12 years experience in the field we have established the dynamics uniquely behind each of our systems. Our dual proportional coatings rig allows us mobilization with the capacity to be self sufficient and finishing your project on time and on budget. Spray Coating


Condensation - It can seem like a tropical rain forest inside an unprotected metal building. It's worse on those days where there is a greater contrast between temperatures at night vs. day. The morning sun hitting the cool sheeting will create a drip. A temperature difference between outside and inside your building creates condensation - Similar to what happens when you leave a cold can of beer outside on a hot day. 
Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through:

The PPG logo is a registered trademark and Colorful Communities and We protect and beautify the world are trademarks of PPG Industries Ohio, Inc. © 2018 PPG Industries, Inc. All Rights Reserved. | Legal Notices & Privacy Policies | CA Transparency in Supply Chain Disclosure | Global Code of Ethics | TISC for PPG Architectural Coatings UK Limited | TISC for PPG Industries (UK) Limited | PPG Industries UK Ltd 2017 Gender Pay Gap Report Insulation Spray Coating

Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close
I've used P&S BeadMaker, Meguiars Express Wax, Carnuba Wax, CMX and most recently Meguiars Hybrid Wax. To tell you the truth, if you're a gloss and slick addict, it really boils down to how well you prep your car. Wash, clay bar, compund, and polish. IPA wipe down. Anything else you put on after will highlight the shine you prepped with all the pre-work. Spray Coating
There are exceptions to the thermal barrier rules. If the spray foam insulation is used as roofing or covered by concrete whichis, at least, an inch thick, then thermal barriers are not necessary. Additionally, you do not have to use a thermal barrier if the spray foam insulation is used on the interior of sill plates and rim joists, so long as the spray foam is 3 1/4 inches or less. Thermal barriers are also not necessary if the spray foam insulation is used in an attic or crawl space, as long as they are not used for storage or as living areas. In attics and crawl spaces where thermal barriers are not required, the use of ignition barriers is necessary. Insulation Spray Coating

This technique is mostly used to produce coatings on structural materials. Such coatings provide protection against high temperatures (for example thermal barrier coatings for exhaust heat management), corrosion, erosion, wear; they can also change the appearance, electrical or tribological properties of the surface, replace worn material, etc. When sprayed on substrates of various shapes and removed, free-standing parts in the form of plates, tubes, shells, etc. can be produced. It can also be used for powder processing (spheroidization, homogenization, modification of chemistry, etc.). In this case, the substrate for deposition is absent and the particles solidify during flight or in a controlled environment (e.g., water). This technique with variation may also be used to create porous structures, suitable for bone ingrowth, as a coating for medical implants. A polymer dispersion aerosol can be injected into the plasma discharge in order to create a grafting of this polymer on to a substrate surface.[3] This application is mainly used to modify the surface chemistry of polymers.
We highly recommend the Rubberseal as the best roof coating. It is waterproof and protective, while having less odor and volatile organic compounds. It would be perfect for those who do roof coating as a daily job.The Rubberseal is designed to provide a reliable seal for all types of waterproofing applications. It’s ideal for both home and industry uses.
Spraying paint with compressed air can be traced back to its use on the Southern Pacific Railway in the early 1880s[1] In 1887 Joseph Binks, the maintenance supervisor at Chicago's Marshall Field's Wholesale Store developed a hand pumped cold-water paint spraying machine to apply whitewash to the subbasement walls of the store.[2][3] Francis Davis Millet, the decorations director for the World's Columbian Exposition in Chicago in 1893, used Binks and his spray painting system to apply whitewash consisting of a mix of oil and white lead to the buildings at the Exposition, taking considerably less time than traditional brush painting and tuning it into what has been called the White City.[4][1][3] In 1949, Edward Seymour developed a type of spray painting, aerosol paint, that could be delivered via a compressed aerosol in a can. Spray Coating
×