This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.) Spray Coating Services

If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
Synavax™ thermal insulation coatings are the top choice for a wide variety of thermal insulating paint applications over equipment like pipes, pipelines, tanks, ovens, processing vessels, heat exchangers and more. Synavax™ patented industrial thermal insulation paint solves corrosion-under-insulation (CUI) by both insulating and preventing corrosion with a single product. Our thermal paint coatings are multipurpose spray or paint applied products that are simple to deploy. Spray Coating Services

You like to make the tough call and enjoy having the authority to make decisions in the best interests of your customers. At PPG Coatings Services, we value those traits because our industry is constantly changing. In our business, you can't always wait for a decision, a change or a result. We constantly invest in our business, but we also invest in you, providing the skills, technical knowledge and independence you need to create loyal, satisfied and successful customers. Spray Coating Services
The long answer is more complicated. There are instances where ignition and thermal barriers are required, and others where they are not. It is all dependent on the location of the insulation. Additionally, the materials that satisfy the requirements of ignition and thermal barriers vary. In some circumstances, such as the use of an intumescent coating, an ignition or thermal barrier may not be necessary. It is important to check with your local code inspector to make sure that your use of spray foaminsulation and ignition barriers is correct.
Henry 587 100% Acrylic Dura-Brite White Elastomeric Roof Henry 587 100% Acrylic Dura-Brite White Elastomeric Roof Coating is a premium high solids reflective roof coating. Its elongation peel strength and solar reflectance values offer weather protection high solar reflectivity and superior longevity when compared to economy grade reflective roof coatings. When cured it allows moisture vapor to vent ...  More + Product Details Close
Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier.
You are eligible for a full refund if no ShippingPass-eligible orders have been placed. You cannot receive a refund if you have placed a ShippingPass-eligible order. In this case, the Customer Care team will remove your account from auto-renewal to ensure you are not charged for an additional year and you can continue to use the subscription until the end of your subscription term.
Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include: Spray Coating Services
Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close
Proper storage: Since, paints and thinners are fire hazards, extra care must be taken not only while they are in use. Fire safety should also be considered when storing paint supplies.[10] In the United States, the Occupational Safety and Health Administration (OSHA) provides guidelines for the proper storage of flammable materials.[11] Many products used in spray painting are flammable such that fire risk is likely within a distance of 15 cm from the nozzle. As such, ignition sources must be placed at a safe distance. In addition, there is a risk of dust explosions when finely-divided paint particles become airborne. Insulation Spray Coating

Appropriate training for personnel who are responsible for conducting the painting procedures is important, which may be from a professional training provider or the product supplier. There are also hazards related to the disposal of wastes and materials that are contaminated with potentially harmful chemicals. Decontamination procedures and Material Safety Data Sheets for various products are important. Safety is improved through: Coating Services

Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings.
Personal protective equipment (PPE) use: PPE must be used when handling spray paint materials, particularly PPE that offers protection to the skin. Some of the essential personal protective equipment are overalls with a hood, protective goggles for the eyes, half-mask respirators, and single use nitrile gloves. One of the most essential types of PPE is respiratory protective equipment (RPE). Nevertheless, basic RPE does not offer ample protection from the negative effects of isocyanates in human tissue. Paint products containing isocyanates must be handled while donning an air-fed RPE that has a 20 or higher APF (assigned protection factor). Air-fed respiratory protective equipment needs extra attention since they provide breathable air to the user. When in use, measures must be implemented to prevent contamination of the air supply since there is a risk of harmful substances entering the intake valve if it is not positioned outside of the spray area.
HVOF coatings may be as thick as 12 mm (1/2"). It is typically used to deposit wear and corrosion resistant coatings on materials, such as ceramic and metallic layers. Common powders include WC-Co, chromium carbide, MCrAlY, and alumina. The process has been most successful for depositing cermet materials (WC–Co, etc.) and other corrosion-resistant alloys (stainless steels, nickel-based alloys, aluminium, hydroxyapatite for medical implants, etc.).[1]
You want to know when the job has been done well and when it didn't go as expected. You take accountability for your actions and understand that in business, results matter more than intentions. As empowered decision makers, PPG Coatings Services team members take pride in their ability to help customers overcome their toughest challenges, while sharing in the rewards and satisfaction that come with a job well done. Insulation Spray Coating
The fluid pressure is provided by an airless pump, which allows much heavier materials to be sprayed than is possible with an airspray gun. Compressed air is introduced into the spray via an air nozzle (sometimes called air cap) similar to a standard conventional spray gun. The addition of compressed air improves the fineness of atomization. Additionally unlike a pure airless spray gun, an AA gun has some control over fan spray to round spray. Some electric airless sprayers (Wagner and Graco) are fitted with a compressor to allow the use of an air-assisted airless gun in situations where portability is important.
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend? Insulation Spray Coating
This is where things get a little tricky. If a home has spray foam insulation in an attic or crawl space, the building code requires using materials or assemblies that offer some fire resistance but not as much as is required for a thermal barrier. If you've got spray foam insulation in an attic, for example, it's probably already separated from the living space by a thermal barrier. Most ceilings are made of 1/2" drywall. But the spray foam is still exposed to the attic and needs an ignition barrier.
Schweitzer Spray Coatings is a family owned and operated business, located in West Bend WI. Our company serves a wide variety of roof coatings to Agriculture/Farms, Commercial/Industrial and Residential Accounts. We specialize in coating buildings, pole sheds, barns, and trailers. If you are experiencing any leaks, rust, or just need a new paint coating, contact us today for your rubber roof solution. Spray Coating

A spray booth is a pressure-controlled closed environment, originally used to paint vehicles in a body shop. To ensure the ideal working conditions (temperature, air flow, and humidity), these environments are equipped with ventilation, consisting of mechanical fans driven by electric motors, and optionally burners to heat the air to speed paint drying. Toxic solvents and paint particles are exhausted outside, possibly after filtering and treatment to reduce air pollution. Prevention of fires and dust explosions is also a high priority. In order to assist in the removal of the over sprayed paint from the air and to provide efficient operation of the down-draft, water-washed paint spray booths utilize paint detackifying chemical agents.
We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock. Coating Services
Fiberglass is also rated in terms of thickness. “Six inches of fiberglass insulation might get an R-19 rating,” says Pritchett, “but how many builders will cram that six inches of insulation into four inches of stud wall? That R-19 rating doesn’t account for compression of the product.” SuperTherm achieves an R-19 rating with one coat applied, and a rating of R-28.5 when the surface is coated on the exterior and interior.
I guess I'm saying all of these products are good, they will complement the work you do on your car if you're willing to put the time into it. And it will make it easier to maintain the next time you wash your car. If you don't clay and polish your car, don't expect super slick results. If you put the work into it, when you spray the car down with water, use a soap wash, rinseless wash, it will still shiny after you put any product on it! Don't get caught up in the SIO2 hype, just spend what you're willing to pay for the product. You'll be happy with any product.
FIRESHELL® (F10E) is a proprietary non-flammable, intumescing (expands up to 2000%) interior coating that provides oxygen starvation to fire. It is a non-toxic, water based, drain safe, no fuming GREEN product. FIRESHELL® passes full scale room corner over foam, NFPA 286 and E84 class A certified. Meets requirements for 15 minute thermal barrier. It is a water-based one part coating system that comes white but can be tinted different colors. This coating can be top-coated with either latex or oil based coating.
Yes, absolutely. If you put spray foam insulation in a building, it needs a thermal barrier. That's what separates it from the occupied spaces. If there's a fire in the building, a thermal barrier keeps the combustible spray foam from the flames to increase fire resistance. The International Residential Code (IRC) and Internation Building Code (IBC) both include requirements for thermal barriers (and ignition barriers, too; see below). Coating Services
Building code regulations typically call for the use of thermal barriers when spray polyurethane foam is installed. The code requires that the foam is separated from any living spaces by a layer of 1/2-inch drywall. As discussed earlier, any material that has been approved as being as equally fire resistant as the gypsum drywall can be substituted as a thermal barrier. Spray Coating
×